convenient position (fig. 16) and the motor is
switched off.
When you lift the tube from the rest the motor will
start again automatically.
Storage
- Switch the vacuum cleaner off (fig. 17).
- Remove the mains plug from the wall socket.
- Rewind the mains cord by pressing the
cordwinder pedal (i) (fig. 18).
- Hitch the lower tube onto the vacuum cleaner
(fig. 19-20). You can slide the clip along the
tube to change the height.
Replacing the dustbag
Only use this vacuum cleaner with the original
Philips dustbags types Oslo
+
(type nº.
HR 6938 or service nº. 4822 015 70049) or
Oslo
+
Hygiene (closeable) (type nº.
HR 6938-OSH or service nº. 4822 015 70057)
(fig. 21). Damage due to using other dustbags
is not covered by guarantee.
The "dustbag full indicator" will indicate when
the dustbag is full (fig. 22).
- Switch the vacuum cleaner off (fig. 17).
- Remove the hose (fig. 1b).
- Open the cover (fig. 23).
- Remove the cassette with the full dustbag
(fig. 24).
- Remove the full dustbag from the cassette by
pulling the cardboard tag (fig. 25).
This automatically closes the dustbag (type
Oslo
+
Hygiene).
- Discard the full dustbag.
- Slide the cardboard front plate of the new
dustbag into the two slots of the cassette as far
as possible (fig. 26-27).
- Position the cassette and the new dustbag in
the vacuum cleaner (fig. 28).
- Bend the rear part of the dustbag downwards.
- Close the cover ("Click!") (fig. 29).
Note: If no dustbag has been placed into the
cassette, the cover cannot be closed.
Replacing the motor protection filter
After having removed the full dustbag, you can
see the removable holder with the motor
protection filter.
Replace the motor protection filter when placing
the first of a new set of dustbags.
You can take the holder to the dustbin and shake
the filter out there. Hygienic: you need not touch
the filter.
Position the new filter with the white side towards
the dustbag (fig. 30-32).
Press the holder with the new filter firmly into
place to ensure that it fits in correctly at the
bottom.
S-Class filter
This revolutionary S-Class filter was especially
designed for Philips Vision vacuum cleaners.
The S-Class filter is capable of removing from the
outlet air at least 99.97% of all the particles
measuring 0.0003 mm and more.
This includes not only normal domestic dust, but
also harmful microscopic vermin such as
glycyphagii and their excrements.
These are known as causes of bronchial
allergies.
To guarantee optimum air filtering, the S-Class
filter needs replacement at least once a year.
For replacement, single S-Class filters are
available from your dealer under type
n°. HR 6992 or service n°. 4822 480 10084.
How to replace the S-Class filter
- Open the filter holder (fig. 33).
- Remove the old filter (fig. 34).
- Place the new filter as indicated in fig. 35-37.
Replacing the mains cord
If the mains cord of this appliance is damaged, it
must only be replaced by Philips or their service
representative, as special tools and/or parts are
required.
Extra accessories
To enable you have even better profit from your
Philips Vision vacuum cleaner, some extra
accessories are available from your dealer:
Turbo nozzle HR 6988 (fig. 38)
This turbo nozzle has been especially designed
for enhanced cleaning of rugs and carpets.
The rotating brush effortlessly picks up small
threads, hairs, fluff and more difficult to vacuum
particles.
Good in-depth cleaning is guaranteed with the
turbo nozzle.
Hard floor nozzle HR 6943 (fig. 39)
This nozzle is especially advisable for large
surfaces of parquet, tiles, etc.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Philips hr 8893 vision plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Philips hr 8893 vision plus in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info