301428
80
Zoom out
Zoom in
Previous page
1/88
Next page
ErgoLine D310/320
Customer Engineer Manual
Page 5-6
PNT1 (for use with 4-wire interface)
The ErgoLine D310 and D320 can be connected to the Switch via a Private
Network Termination (PNT1).
The EAZ of the ErgoLine D310/D320 should be adjusted as if the terminal was
connected to an S0-bus.
The PNT1 is equipped with two eight way modular sockets for the connection of
two S
0
ErgoLine terminals. On both jacks the corresponding pins 3, 4, 5 and 6 are
interconnected: 3 to 3, 4 to 4, etc.
Pin Outs
Pin
Signal
1 n/c
2 n/c
3 Receive +
(power +)
4 Transmit +
(power -)
5 Transmit -
(power -)
6 Receive -
(power +)
7 n/c
8 n/c
S
0
Interface
This interface is the standard SOPHO iS3000 S
0
interface.
To identify the terminal at the S
0
-bus see the section entitled
Endgerät Auswahl
Ziffer (EAZ)
below.
U
PN
interface
The ErgoLine D310 and D320 can be connected to the switch via the DLX-U U
PN
interface. This is a two wire digital interface which uses ping-pong signalling. (Do
not mistake this interface with the echo-cancelling proprietary Philips U-interface).
This interface is capable of supporting the connection of one terminal only.
Normally, the DLX-U U
PN
board should be projected in 1B mode for D310/D320
terminals.
The D310 and D320 terminal may also replace a D340 terminal that is connected
to a 2B+D mode projected DLX-U board. Remember that 2B+D mode is required
for the D340 when it uses both the voice and the data port. When a D310 or D320
terminal is connected to the DLX-U board in 2B+D mode only one B-channel is
used per port, while the other B-channel is left unused.
80


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Philips ergoline d340 2 dg at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Philips ergoline d340 2 dg in the language / languages: English as an attachment in your email.

The manual is 2,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Philips ergoline d340 2 dg

Philips ergoline d340 2 dg User Manual - Dutch - 99 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info