5. Operation
5.1 Powering the Scales
We recommend using a power adapter if you plan using the scales on a regular basis. If not, powering
the scales with batteries will suffice.
To insert the batteries, proceed as follows:
1. Open the battery compartment of the weighing platform by sliding the cover toward the outside.
2. Insert two AAA batteries according to the correct polarity.
3. Close the battery compartment.
Remark: Remove the batteries or disconnect from the mains if the scales will not be used for a longer
period.
The deported display does not need any powering.
Warning: Do not puncture batteries or throw them in fire as they may explode. Do not
attempt to recharge non-rechargeable batteries (alkaline). Dispose of batteries in accordance
with local regulations. Keep batteries away from children.
Replace the batteries as soon as the display shows “L-O”.
5.2 General Operation
1. Place the scales on a levelled surface.
2. Press the on-off button to switch on the scales.
3. Place the item on the platform and wait until the reading on the display is stable.
4. Switch off the scales after use. Note that the scales will switch off automatically 90 seconds after
the last operation.
The scales are overloaded as soon as the display shows “EEEE”. Remove the item from the
platform.
5.3 Unit Selection
1. Switch on the scales.
2. Press the mode button to select the weighing unit.
5.4 Tare Function
1. Switch on the scales.
2. Place the tare item on the platform.
3. Press the tare button once and wait for the display to show 0.00.
4. Add the net weight.
5.5 Calibration
1. Switch on the scales.
2. Press and hold the mode button and wait for the display to show “CAL”. The required calibration
weight will flash on the display. Put the calibration weight in the centre of the platform.
3. Calibration is complete when the display shows “PASS”.
4. The scales go back to the normal weighing mode.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Perel VTBAL500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Perel VTBAL500 in the language / languages: English, German, Dutch, French, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 0,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info