720262
8
Zoom out
Zoom in
Previous page
1/74
Next page
FT120C/FT130C
V. 05 23/04/2020 8 ©Velleman nv
9. Troubleshooting
Problem
Cause
Remedy
Motor does not start.
E1 is displayed
No power or low voltage.
Check power line and voltage.
Check fuse and replace if
needed.
Faulty or damaged power
cord.
Check and replace if needed.
Faulty motor/capacitor.
Check and replace if needed.
Lock-out of appliance due to
previous overheating.
Detect the cause of
overheating. Switch off the
appliance. Check air inlet and
outlet. Wait some minutes
and restart the appliance.
E2 is displayed
The temperature probe is
faulted or the connector for
temperature probe is loose.
Check and replace the
temperature probe if needed.
Check and replace the PCB if
needed.
Motor runs, but the heater
does not ignite and locks out
after a short time.
E1 is displayed
Empty fuel tank, dirty or
wrong fuel.
Remove wrong or dirty fuel.
Fill the tank with clean diesel
or kerosene.
Fuel filter clogged.
Clean or replace fuel filter.
Air leaks in oil line.
Check hoses, tighten
connections and replace if
needed.
Burner nozzle clogged.
Clean nozzle blowing
compressed air and replace if
needed.
Fuel viscosity increased at low
temperature.
Mix diesel with 10-20 %
kerosene.
Flames come out of flue
outlet.
E1 is displayed
Insufficient airflow into
combustion chamber.
Check air inlet, fan and
motor.
Compressor pressure too
high.
Check air pressure and adjust
if needed.
Heater stops during
operation.
Ambient temperature is
displayed
The room temperature set on
room thermostat has been
reached.
Normal operation. To start,
turn the temperature control
knob clockwise on a higher
setting.
Heater stops during
operation.
E1 is displayed
Flame failure.
Check and remove the
cause(s) of malfunction. To
reset, switch to 0 and then to
I. Call technical service if the
problem persists.
Bad combustion.
Reduced airflow.
Overheating.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Perel FT130C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Perel FT130C in the language / languages: English, German, Dutch, French, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 1,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info