622426
12
Zoom out
Zoom in
Previous page
1/80
Next page
EVM892
29.04.2010 ©Velleman nv
12
The display will show the temperature.
Note: without the thermocouple in place, the display will show the ambient
temperature.
Measuring frequencies
Do not perform frequency measurements in circuits with voltages
> 250V.
Always be careful when working with voltages above 60Vdc or 30Vac rms.
Keep your fingers behind the probe barriers at all times during
measu
r
ement.
Connect the black test lead to the "COM" jack and the red test lead to the
"VHz" jack.
Select the "20KHz" range with the FUNCTION switch.
Connect the test leads to the circuit under test.
Read the measured value from the display.
Notes:
Use a shielded cable for measuring small signals in a noisy environment (min.
visible amplitude: 0.7Vpp).
10. Specifications
This device is not calibrated when purchased!
Regulations concerning environment of use:
Use this meter only for measurements in CAT I and CAT II environments (see
§4)
Use this meter only in a pollution degree 2 environment (see §5)
Ideal temperature 23°C
Ideal relative humidity 75%
Max. altitude 2000m
Overvoltage/installation category 600V CAT. II
Pollution degree Pollution degree 2
Max. voltage between terminal and
earth
600VDC or 600Vrms AC (sine wave)
Display 3 ½ digit LCD, 2 to 3 readings/sec.
Fuse protection 200mA-range: F 0.2A/250V resettable
10A-range: ceramic F10A/250V
Power supply 9V-battery 6LF22 (only use non-
rechargeable batteries)
Ranging method manual
Polarity indication " - " is displayed
Overrange indication " 1. " is displayed automatically
Battery-low indication
" " is displayed
Operating temperature 0°C to 40°C
Storage temperature -10°C to 50°C
Dimensions 88 x 170 x 38mm
Weight 340g (incl. battery)
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Perel EVM892 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Perel EVM892 in the language / languages: English, German, Dutch, French, Portuguese, Spanish as an attachment in your email.

The manual is 0,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info