Cerberus ADSL Wi-Fi Lite
22
ATM VC
ATM settings are used to connect to your ISP. Your ISP provides VPI, VCI, settings to
you. In this Device, you can totally setup 8 PVCs on different encapsulations if you apply
8 different virtual circuits from your ISP. You need to activate the VC to take effect. For
PVCs management, you can use ATM QOS to setup each PVC traffic line’s priority.
Virtual Circuit Select the VC number you want to setup.
VPI – Virtual Path Identifier. The valid range for the VPI is 0 to 255.
VCI Virtual Channel Identifier. The valid range for the VCI is 1 to 65635 (0 to 31 is
reserved for local management of ATM traffic).
ATM QoS Select the Quality of Service types for this Virtual Circuit. The ATM QoS
types include CBR (Constant Bit Rate), VBR (Variable Bit Rate) and UBR (Unspecified
Bit Rate). These QoS types are all controlled by the parameters specified below,
including PCR, SCR, and MBS.
PCR (Peak Cell Rate)Peak Cell Rate (PCR) is the maximum rate at which the sender
can send cells. This parameter may be lower (but not higher) than the maximum line
speed. 1 ATM cell is 53 bytes (424 bits), so a maximum speed of 832 Kbps gives a
maximum PCR of 1962 cells/sec. This rate is not guaranteed because it is dependent on
the line speed.
SCR (Sustained Cell Rate) – Sustained Cell Rate (SCR) is the mean cell rate of a burst,
on-off traffic source that can be sent at the peak rate, and a parameter for burst-type
traffic. SCR may not be greater than the PCR; the system default is 0 cells/sec.
MBS (Maximum Burst Size) Maximum Burst Size (MBS) is the maximum number of
cells that can be sent at the PCR. After MBS is reached, cell rates fall below SCR until
cell rate averages to the SCR again. At this time, more cells (up to the MBS) can be sent
at the PCR again.
CBR (Constant Bit Rate) – is for connections that support constant rates of data
transfer. The only parameter you need to worry about in CBR is PCR.
UBR (Unspecified Data Rate) is for connections that have variable traffic. The only
parameter you need to worry about in UBR is PCR.
rtVBR (real time Variable Bit Rate) is for connections that, while having variable
traffic, require precise timing between traffic source and destination. PCR, SCR and MBS
must all be set for rtVBR.
nrtVBR (non real time Variable Bit Rate) is for connections that have variable traffic,
do not require precise timing, but still require a set bandwidth availability. PCR, SCR and
MBS must all be set for nrtVBR.
Encapsulation
Select the encapsulation protocol your ISP uses. The following section will vary
depending on which encapsulation protocol you select.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for PENTAGRAM Cerberus P 6331-4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of PENTAGRAM Cerberus P 6331-4 in the language / languages: English as an attachment in your email.

The manual is 1,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info