329340
35
Zoom out
Zoom in
Previous page
1/74
Next page
33
Installation
General
When the appliance is not fitted with a power
cord with plug, the appliance may only be
connected by a qualified electician.
Please note:
The correct voltage for the appliance and the
connection value are shown on the rating plate
at the back of the oven. Always comply with
local regulations when connecting the
appliance.
U.K. only
To connect the appliance a fixed connection has
to be made. The wire which is coloured green
and yellow must be connected to the terminal
which is marked by the letter E or the earth
symbol or which is coloured green, or green
and yellow. The wire which is coloured blue
must be connected to the terminal which is
marked by the letter N or which is coloured
black. The wire which is coloured brown must be
connected to the terminal which is marked by
the letter L or which is coloured red. If the input
of the appliance acceeds 3 kW, the appliance
has to be connected to an outlet with a rated
current exceeding 13 Amp.
Electrical connection
230 V - 50 Hz.
Make sure the appliance has an earth wire
connection. Use good quality cable for
connecting, e.g. H05RRF, 1,5 or 2,5 mm
2
, with 3
or 5 cores, depending upon the regulations.
With following colour code:
brown = phase L
blue = phase N
green/yellow = earth ( )
black = neutral or phase
Depending upon the wiring diagram, you can
use the black cores for neutral or a phase.
The cable must have a plug suitable for a
nominal load of at least 15 A.
If you want to make a fixed connection,
ensure that a multi-pole switch with a
distance between contacts of 3 mm is
installed in the supply cable.
Wiring diagrams
There is a label showing the wiring diagrams
on the underside of the appliance.
Supply terminals
The supply terminals are accessible by
removing the cover plate on the underside.
You can make the cross connections needed
using the jumpers on the terminal block.
Do not forget to secure the cable with the
cable clamp. Refit the cover plate after you
have secured the cable.
INSTALLATION
88015902_HL_OKW955_95 11-03-2004 13:36 Pagina 33
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Pelgrim osk 995 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Pelgrim osk 995 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info