119118
Ensure that the connection cables hang freely. If there is a drawer underneath
the hob, make sure that the contents do not project above the edge of the
drawer and interfere with the ventilation.
Installation of the induction hob above a combi-microwave oven, a 90 cm
Pelgrim oven or an oven of a different brand
Saw out the ventilation opening(s),
making sure that the total surface of
the holes is a minimum of 100 cm
2
. See
the drawing, for example, showing
2 holes of 50 cm
2
.
Fit a protective plate between the oven
and the hob. The plate should be at
least 10 mm thick and heat-resistant
(85 °C). The space between the
underside of the hob and the
protective plate must be at least
50 mm.
To protect the air flow, fit a protective
panel - of the same material as the
protective plate - between the
protective plate and the hob.
Ventilation is via the adjoining
cupboards.
Install the appliance in such a way that the power plug remains accessible
always.
min.
installationinstallation
Possibilities for building in
Ventilation
The electronics in the appliance
require cooling. The ventilation
openings are located on the underside
of the appliance. It must be possible
for cool air to be drawn in through
these openings. The appliance is fitted
with outlet openings at the front.
The kitchen unit will require a few modifications to allow optimum cooling of
the hob.
Above drawer or fixed panel
Saw out the ventilation openings
(min. 100 cm
2
). Ventilation is via plinth
and rear of cupboard.
Do not allow the ventilation openings
on the underside of the appliance to
be blocked by a drawer.
Where there is a drawer, a gap of at
least 560 x 3 mm should be made at
the front. The distance between drawer
A and the hob should be a minimum of
10 mm. No extra modifications for
ventilation need be made where there
is a fixed panel.
min.