38 CLEANING/INSTALLATION
fig. 16d
■ Remove the lower spray arm.
■ Remove the filter group (C). Press the lips
together slightly and unscrew the filter
group by turning it to the left
(anticlockwise) (1).
Take out the filter assembly by pulling it
vertically upwards (2) (see fig. 16a).
■ Remove the microfilter (D). Push it out of
the housing from underneath (see fig. 16b).
■ Remove the filter (F). Pull the filter out of
the filter housing vertically (see fig. 16c).
■ Remove the large filter (G) (see fig. 16d).
■ Clean filters F and G under running water
with a brush.
■ Reassemble the filter mesh and filter in
reverse order.
Installation
Electrical connection
230 V – 50 Hz
General
If the appliance does not have a connecting
cable and plug, then it may only be connected
to the mains by an approved installer.
Note:
The power rating and required mains voltage
are shown on the rating plate. Connection
should take place according to national and
local regulations.
If the input of the appliance exceeds 3 kW, the
appliance has to be connected to an outlet
with a rated current exceeding 13 Amps.
Technical information
Connected load kW see identification
plate
Dimensions:
Max. height mm 870
Min. height mm 820
Width mm 596
Depth mm 550
Door panel:
Max. height mm 720
Min. height mm 650
Depth mm 598
Plinth:
Max. height mm 170
Min. height mm 100