Cut opening in worktop
Saw the opening in the worktop. This should be done very accurately (see
table). Also saw out any partitions that may be present.
The distance from the saw line to the rear wall and/or side wall is indicated in
the table.
Table
Space to be left free around the appliance
95
min. 600 mm (HL60..G en HL60..M)
min. 750 mm (HL70..M)
min. 650 mm
min. 450 mm
min. 40 mm
min. 40 mm
installation guide
Type of hob CKB740
Appliance width x depth 600 x 510 mm
Installation height from top of worktop 48 mm
Cut out dimensions width x depth 560 x 490 mm
Distance from saw line to rear wall 50 mm
Distance from saw line to side wall 60 mm
94
installation guide
3-phase connection (3 a.c. 230 V / 50 Hz):
The voltage between the phases and the neutral is 230 V a.c.
Install connecting bridges between the connection points 4-5. Your groups
must be fused with at least 16 A (3x). The connecting power cable must have a
minimum core cross section of 2,5 mm
2
.
You can use the bridges provided on the connecting block to make the
required interconnections as indicated in the preceding illustrations. How to
install the bridges is indicated in the junction box cover and in the illustration
below. The bridges should not be placed immediately on top of the connecting
wires, but between the screw-head and the clamp around the connecting wire.
Secure the cable with the strain relief and close the cover.