16
INSTALLATION
Electrical connection
230 V -50 Hz
■ The appliance should always be earthed.
Use good quality cable for connecting e.g.
H05RRF, 1,5 or 2,5 mm
2
, with 3 or 5 cores,
depending on the regulations.
With following colour code:
brown = phase L
blue = phase N
green/yellow = earth ( )
black= neutral or phase
Depending upon the wiring diagram, you
can use the black cores for neutral or a
phase.
The cable must have a plug suitable for a
nominal load of at least 15 A.
If you want to make a fixed connection,
ensure that a multi-pole switch with a
distance between contacts of 3 mm is
installed in the supply cable.
To connect the appliance a fixed connection
has to be made. The wire which is coloured
green and yellow must be connected to the
terminal which is marked by the letter E or the
earth symbol or which is coloured green,
or green and yellow. The wire which is
coloured blue must be connected to the
terminal which is marked by the letter N or
which is coloured black. The wire which is
coloured brown must be connected to the
terminal which is marked by the letter L or
which is coloured red. If the input of the
appliance exceeds 3 kW, the appliance has to
be connected to an outlet with a rated current
exceeding 13 Amp.
Disposal of packaging and
appliances
The packaging of the appliance is recyclable.
It is made up off:
- cardboard
- polyethylene
- CFC free polystyrene (PS rigid foam)
- polypropylene straps around the box
Please dispose of these materials in a responsible
way in accordance with the regulations of your local
authority.
Your local authority will also be able to give you
information about disposing disused household
appliances in a responsible way.
This appliance complies the regulations concerning
electromagnetic compatibility in directive 89/336/EEC.