731496
29
Zoom out
Zoom in
Previous page
1/34
Next page
© PCE Instruments
26
How to capture screen
When in DMM mode or Thermal imaging + DMM mode, use HOLD button to enter hold mode, as
shown below. Then press UP button to capture screen. After saving to TF card completely,
multimeter will exit hold mode.
7 Technical specifications
General technical data
Display
Colour TFT, 6000 points with status display
Conversion
TRMS
Reference standards
IEC/EN61010-1, IEC/EN61326-1
Isolation
Double
Pollution degree
2
Overload category
CAT IV 600 V, CAT III 1000 V
Battery type
1 x 7.4V Li-Ion battery, 2300-mAh
Power supply charger
100 / 240V AC, 50/60 Hz, 10V DC, 1 A
Battery level indicator
Yes
Automatic shutdown
After 15, 30 or 60 minutes of inactivity
(deactivatable)
Fuses
F10A/1000V, 10 x 38 mm (Input 10 A)
F800mA/1000V, 6 x 32 mm (Input mA, µA)
Test temperature
18 ... 28°C / 64 ... 82°F
Operating conditions
5 ... 40°C / 41 ... 104°F, <80% r.H.
Storage conditions
-20 ... 60°C / -4 ... 140°F, <80% r.H.
Maximum operating height
2000 m / 2187 yd
Dimensions
175 x 85 x 55 mm / 6.9 x 3.3 x 2.1 in
Weight
540 g / 1 lb 3oz
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for PCE instruments PCE-HDM 20 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of PCE instruments PCE-HDM 20 in the language / languages: English as an attachment in your email.

The manual is 1,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info