parts must be carefully examined in
respect of their proper and intended
function.
- Check whether the moving parts
are working properly and are not
becoming jammed or whether parts
are damaged. All parts must be cor-
rectly tted and satisfy all conditions
to ensure the proper operation of
the power tool.
- Damaged safety equipment and
parts must be repaired properly or
replaced by an authorised specialist
workshop unless otherwise indicat-
ed in the instruction manual.
- Do not use power tools if the switch
cannot be turned on and off. Dam-
aged switches must be replaced at
a customer service workshop.
• Caution!
Using other attachment tools and other
accessories may represent a risk of in-
jury to you.
Have your power tool repaired
by a qualied electrician. This
power tool complies with the relevant
safety regulations. Repairs may only
be performed by a specialist workshop
using original spare parts; otherwise
accidents involving the user may result.
If the connection cable of this device is
damaged, it must be replaced by the
manufacturer or their customer service
or by a similarly qualied person in
order to avoid hazards.
Residual risks
Even if properly operating and handling
this electric tool, some residual risks will
remain. Due to its construction and build,
this electric tool may present the following
hazards:
a) Cuts
b) Ear damage if working without ear pro-
tection.
c) Eye damage if suitable eye protection
is not worn.
d) Damage to your health caused by
swinging your hands and arms when
operating the appliance for longer pe-
riods of time or if the unit is not held or
maintained properly.
Warning! During operation, this
electric tool generates an electro-
magnetic eld which, under certain
circumstances, may impair the
functionality of active or passive
medical implants. To reduce the risk
of serious or lethal injuries, we rec-
ommend that persons with medical
implants consult their doctor and
the manufacturer of their medical
implant before operating the ma-
chine.
Initial start-up
Mounting the bow-type
handle
1. Push the bow-type handle (7) into the
bracket for the bow-type handle (10a)
on the pressure vessel (10).
2. Attach the bow-type handle (7) using
the hexagon socket screws and the en-
closed Allen key (15).
Fitting the wheels
1. Insert the wheel bolt (17) through the
hole in the wheel (11).
2. Insert the wheel bolt (17) through the
hole in the wheel rod.
3. Fasten the wheel (11) using the locknuts
(19). If necessary, use a spanner (not
included in delivery).
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside PVKO 50 A1 - IAN 356332 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside PVKO 50 A1 - IAN 356332 in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 2,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info