19GB/IE/NI/CY/MT
MIG welding
Prevent the risk of an
electric shock, injury or damage. To do
this always unplug the mains plug from
the socket prior to each maintenance
task or preparatory work.
Note: Different welding wires will be
needed depending on the application.
Welding wires with a diameter of
0.6–1.0 mm can be used with this
device.
Feed roll, welding nozzle and wire
cross-section must be compatible with
one another. The device is suitable for
wire reels weighing up to maximum
5000 g.
Use aluminium wire to weld aluminium
and steel wire to weld steel and iron.
Adaptation of device to
solid welding wire with
inert gas
The correct connections for solid wire
welding when using inert gas are shown
in Fig. S. When using the aluminium
solid wire delivered with the product,
then you must use argon as the inert gas
(not included with the delivery).
S
10 4
35
36
6
32
First connect the plug
32
with the
connector marked with the “+”
(see Fig. S). To fi x it in place, rotate
in a clockwise direction. If you are
in any doubt, then please contact a
professional.
Now connect the cable assembly
with direct connection
10
to the
appropriate connector (see Fig. S).
Fix the connection in place by tight-
ening the fi xing ring
38
in a clock-
wise direction.
Then connect the earth cable
4
with the corresponding connector,
marked with the “-” (see Fig. S).
To fi x the connection in place, rotate
in a clockwise direction.
T5
33
Pull the protective cap off the gas
connection
33
.
Now connect the inert gas feed
including the pressure reducer (not
included with the delivery) to the
gas connection
33
(see Fig. T). Inert
gas is required if you are not using
ux-cored wire with integrated solid
inert gas. If necessary, observe the
notes for your pressure reducer (not
included with the delivery). You can
use the following formula as a guide-
line for adjusting the gas fl ow:
38
MIG welding
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside PMSG 200 A1 - IAN 337263 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside PMSG 200 A1 - IAN 337263 in the language / languages: English, German, Dutch, Danish, French, Polish, Spanish as an attachment in your email.

The manual is 2,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info