Whenusing solid wires which do not contain inert gas in solid form, then you must use inert gas in addi-
tion. When using self-shielding flux-cored wire, you do not need to use any additional gas. In this case,
the inert gas is contained in the welding wire in powdered form and is therefore channelled straight into
the arc. This means that the device is not susceptible to wind when working outdoors. Only suitable wire
electrodes may be used for the device. This welding device is designed for manual arc welding (MMA
welding) of steel, stainless steel, steel sheet and cast materials, using the appropriate coated electrodes.
Refer to the information from the electrode manufacturer. Only suitable electrodes may be used for the
device. For tungsten inert gas welding (TIG welding) it is essential that you observe the operating and
safety instructions for the TIG torch you are using, in addition to the instructions and safety instructions in
these operating instructions. If it is not handled properly the product can be dangerous for individuals,
animals and property. Use the product only as described and only for the specific applications as
stated. Keep these instructions in a safe place. Ensure you hand over all documentation when passing
the product on to anyone else. Any use that differs to the intended use as stated above is prohibited and
potentially dangerous. Damage or injury caused by misuse or disregarding the above warning is not
covered by the warranty or any liability on the part of the manufacturer. Commercial use will void the
warranty. Observing the safety instructions and assembly instructions and operating information in the
instructions for use is also a component of the intended use. It is imperative to adhere to the applicable
accident prevention regulations. The device must not be used:
in insufficiently ventilated rooms,
in explosive environments,
to defrost pipes,
in the vicinity of people with cardiac pacemakers and
in close proximity to easily flammable materials.
Residual risk
Even if you operate the device as intended, there will be residual risks. The following dangers may occur
in connection with the build and design of this MIG pulse welder:
Eye injuries caused by glare, touching hot parts of the device or workpiece (burn injury),
In case of improper protection, risk of accident and fire through sparks and slag particles,
Harmful emissions from smoke and gases if there is a lack of air or if closed rooms are insufficiently
extracted.
PLEASE NOTE: Reduce the residual risk by carefully using the device as intended and observing
all instructions.
zPackage contents
1 Multi-Welder with Double Pulse Technology 200 A1
1 MIG welding torch with 2 m welding cable
1 high-quality, galvanised copper earth terminal, A-shape with 2 m cable
1 electrode holder MMA with 2 m welding cable
4 contact tips for steel/flux-cored wire (1x 0.6 mm; 1x 0.8 mm; 1x 0.9 mm; 1x 1.0 mm)
Labelling in accordance with the diameter: 0.6; 0.8; 0.9; 1.0
1 aluminium nozzle (1x 1.0 mm pre-fitted)
1 chipping hammer
1 welding core for aluminium wire (pre-fitted)
1 welding core for steel/stainless steel and flux-cored wire
1 set of operating instructions
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside PMPS 200 A1 - IAN 389215 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside PMPS 200 A1 - IAN 389215 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 6.17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info