4. Proper use
The compressor is designed to generate com-
pressed air for compressed-air driven tools which
can be driven with an air volume of up to approx.
400 l/min (e.g. a tire infl ator, blow-out pistol and
paint spray gun). Compressed air tools with very
high air consumption have only limited suitability
for use with this compressor. For tools with high air
consumption (e.g. orbital sanders/grinders, rod
grinders, hammer screwdrivers), check whether
the compressor’s air output is suffi cient to operate
the tool in question. The volume of air supplied by
the compressor must be greater than the volume
of air consumed by the compressed air tool at its
operating pressure.
The equipment is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the manufac-
turer will be liable for any damage or injuries of
any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
5. Technical data
Mains connection: .........................230 V ~ 50 Hz
Motor rating kW: ........................................2.2 kW
Operating mode: ................................................S1
Compressor speed min
-1
: .............................. 2850
Operating pressure bar: ..............................max. 8
Pressure vessel capacity (in liters): .....................50
Theoretical intake capacity (l/min): .approx. 400
Effective delivery rate at 7 bar: approx. 160l/min
Sound power level L
WA
in dB: .............................97
K
WA
uncertainty: ...............................................4 dB
Protection type: ................................................IP20
Weight of the unit in kg: ......................................44
Oil (15W 40): ..................................................0.3 l
The product meets the requirements of EN
61000-3-11 and is subject to special con-
nection conditions. This means that use of the
product at any freely selectable connection
point is not allowed.
Given unfavorable conditions in the power
supply the product can cause the voltage to
fluctuate temporarily.
The product is exclusively intended for use
at connection points that have a continuous
current-carrying capacity of at least 100 A
per phase.
As the user, you are required to ensure, in
consultation with your electric power compa-
ny if necessary, that the connection point at
which you wish to operate the product meets
the specified requirements.
6. Before starting the
equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Check the equipment for damage which may
have occurred in transit. Report any damage
immediately to the transport company which
was used to deliver the compressor.
Install the compressor near the point of con-
sumption.
Avoid long air lines and supply lines (extensi-
on cables).
Make sure that the intake air is dry and dust-
free.
Do not install the compressor in a damp or
wet room.
The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5 °C to 40 °C). There must
be no dust, acids, vapors, explosive gases or
inflammable gases in the room.
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor in
areas where work is conducted with sprayed
water.
The oil level in the compressor pump has to
Anleitung_4010411_LB2.indb 53Anleitung_4010411_LB2.indb 53 12.03.12 09:5212.03.12 09:52
53


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside PKO 400 A1 - IAN 73783 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside PKO 400 A1 - IAN 73783 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info