11. Possible causes of failure
Problem Cause Solution
The compressor does not
start.
1. No supply voltage.
2. Insufficient supply voltage.
3. Outside temperature is too
low.
4. Motor is overheated.
1. Check the supply voltage,
the power plug and the
socket-outlet.
2. Make sure that the
extension cable is not too
long. Use an extension cable
with large enough wires.
3. Never operate with an
outside temperature of
below +5° C.
4. Allow the motor to cool
down. If necessary, remedy
the cause of the overheating.
The compressor starts but
there is no pressure.
1. The non-return valve leaks.
2. The seals are damaged.
3. The drain plug for
condensation water (9)
leaks.
1. Have a service center
replace the non-return valve.
2. Check the seals and have
any damaged seals replaced
by a service center.
3. Tighten the screw by hand.
Check the seal on the screw
and replace if necessary.
The compressor starts,
pressure is shown on the
pressure gauge, but the
tools do not start.
1. The hose connections (G,
H) have a leak.
2. A quick-lock coupling (5, 20)
has a leak.
3. Insufficient pressure set on
the pressure regulator (4).
1. Check the compressed air
hose and tools and replace if
necessary.
2. Check the quick-lock
coupling and replace if
necessary.
3. Increase the set pressure
with the pressure regulator.
Anleitung_LB5_4010404:_ 24.02.2011 11:09 Uhr Seite 54
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside PKO 270 B2 - IAN 64575 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside PKO 270 B2 - IAN 64575 in the language / languages: English, German, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Parkside PKO 270 B2 - IAN 64575

Parkside PKO 270 B2 - IAN 64575 User Manual - German, Dutch - 32 pages

Parkside PKO 270 B2 - IAN 64575 User Manual - French - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info