6. Technical data
Mains connection 220 - 240 V ~ 50Hz
Motor rating W
1800
Operating mode
S1
Compressor speed
2850 min
-1
Pressure vessel capacity (in liters)
approx. 24
Operating pressure
approx. 10 bar
Theoretical intake capacity (l/min)
approx. 260
sound power level L
WA
97 dB(A)
uncertainty K
WA
3 dB
Protection type
IP20
Weight of the unit in kg
approx. 27
Oil (15W 40) l
approx. 0,6
Max. altitude
(above mean sea level)
1000 m
The noise emission values were measured in accordance
with EN ISO 3744:1995.
Wear hearing protection.
The effects of noise can cause a loss of hearing.
7. Before starting the equipment
Before you connect the equipment to the mains supply
make sure that the data on the rating plate are identical to
the mains data.
Check the equipment for damage which may have oc-
curred in transit. Report any damage immediately to
the transport company which was used to deliver the
compressor.
Install the compressor near the point of consumption.
Avoid long air lines and supply lines (extension cables).
Make sure that the intake air is dry and dustfree.
Do not install the compressor in a damp or wet room.
The compressor may only be used in suitable rooms
(with good ventilation and an ambient temperature from
+5 °C to 40 °C). There must be no dust, acids, vapors,
explosive gases or inflammable gases in the room.
The compressor is designed to be used in dry rooms. It
is prohibited to use the compressor in areas where work
is conducted with sprayed water.
The oil level in the compressor pump has to be checked
before putting the equipment into operation.
8. Attachment and operation
m Important!
You must fully assemble the appliance before using it
for the first time!
You will require the following tools for assembly and instal-
lation: Open-ended wrench size 12, 13 and 14 mm (not
included)
8.1 Fitting the wheels (Fig. 4,5)
Fit the supplied wheels as shown.
8.2 Fitting the supporting feet (Fig. 4,6)
Fit the supplied supporting foot as shown.
8.3 Fitting the air filter (Fig. 7,8)
Remove the transportation stop (B) and screw the air fil-
ter (15) to the equipment.
8.4 Changing the transportation cover (A) (Fig. 9,10)
Remove the transportation cover from the oil filter open-
ing (20) and insert the supplied oil sealing plug (16)
into the oil filler opening.
8.5 Mains connection
The compressor is equipped with a mains cable with
shock-proof plug. This can be connected to any 220 -
240 V~ 50 Hz shock-proof socket.
Before you use the machine, make sure that the mains
voltage is the same as the operating voltage (see the
rating plate).
Long supply cables, extensions, cable reels etc. cause a
drop in voltage and can impede motor start-up.
At low temperatures below +5°C, sluggishness may
make starting difficult or impossible.
8.6 ON/OFF switch (Fig. 2)
Pull the ON/OFF switch (17) upwards to switch on the
compressor. To switch off the compressor, press the
ON/OFF switch down.
8.7 Setting the pressure (Fig. 1,3)
Use the pressure regulator (5) to set the pressure on the
pressure gauge (4).
The set pressure can be drawn from the quick lock cou-
pling (3).
The vessel pressure can be read off the pressure gauge
(6).
The vessel pressure is drawn from the quick lock cou-
pling (7).
8.8 Setting the pressure switch (Fig. 1)
The pressure switch (2) is set at the factory.
Cut-in pressure approx. 8 bar
Cut-out pressure approx. 10 bar.
8.9 Fitting the compressed air hose (Fig. 1, 3)
Use the compressed air hose (14) if you intend to carry
out work at a greater distance from the compressor. To
do so, connect the nipple (H) on the compressed air
hose to one of the quick release couplings (3, 7). Then
attach the compressed air tool to the quick-release cou-
pling (I) on the compressed air hose.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside PKO 270 A3 - IAN 285200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside PKO 270 A3 - IAN 285200 in the language / languages: English, German, Dutch, Danish, French as an attachment in your email.

The manual is 5,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info