595285
39
Zoom out
Zoom in
Previous page
1/44
Next page
34 GB
maximum  lling quantity. Over lling the equipment may
result in damage. Reinsert the oil sealing plug (16) into
the oil  ller opening (21).
10.6 Cleaning the intake lter (Fig. 3, 12, 13)
The intake  lter prevents dust and dirt being drawn in.
It is essential to clean this  lter after at least every 300
hours in service. A clogged intake  lter will decrease
the compressor’s performance dramatically. Open the
thumb screw (E) to the remove the intake lter.
Then pull off the  lter cover (C). Now you can remove
the air  lter (F) and the  lter housing (D). Carefully tap
out the air  lter,  lter cover and  lter housing. Then
blow out these parts with compressed air (approx. 3 bar)
and reinstall in reverse order.
10.7 Storage
n Important!
Pull out the mains plug and ventilate the equipment
and all connected pneumatic tools. Switch off the
compressor and make sure that it is secured in
such a way that it cannot be started up again by any
unauthorized person.
n Important!
12. Troubleshooting
Fault Possible cause Remedy
The compressor does
not start.
No supply voltage.
Insuf cient supply voltage.
Outside temperature is too low.
Motor is overheated.
Check the supply voltage, the power plug and the
socket-outlet.
Make sure that the extension cable is not too
long. Use an extension cable with large enough
wires.
Never operate with an outside temperature of
below +5° C.
Allow the motor to cool down. If necessary,
remedy the cause of the overheating.
The compressor starts
but there is no pressure.
The non-return valve leaks.
The seals are damaged.
The drain plug for condensation water (9)
leaks.
Have a service center replace the non-return
valve.
Check the seals and have any damaged seals
replaced by a service center.
Tighten the screw by hand. Check the seal on the
screw and replace if necessary.
The compressor starts,
pressure is shown on
the pressure gauge, but
the tools do not start.
The hose connections have a leak.
A quick-lock coupling has a leak.
Insuf cient pressure set on the pressure
regulator (3).
Check the compressed air hose and tools and
replace if necessary.
Check the quick-lock coupling and replace if
necessary.
Increase the set pressure with the pressure
regulator.
Store the compressor only in a dry location which
is not accessible to unauthorized persons. Always
store upright, never tilted! Oil may leak out!
10.7.1 Releasing excess pressure
Release the excess pressure by switching off the com-
pressor and using the compressed air which is still left
in the pressure vessel, e.g. with a compressed air tool
running in idle mode or with a blow-out pistol.
11. Disposal and recycling
The equipment is supplied in packaging to prevent it
from being damaged in transit. The raw materials in
this packaging can be reused or recycled. The equip-
ment and its accessories are made of various types of
material, such as metal and plastic. Defective compo-
nents must be disposed of as special waste. Ask your
dealer or your local council.
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside PKO 270 A1 - IAN 109808 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside PKO 270 A1 - IAN 109808 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info