Degree of protection .........................IPX5
Rated/operating pressure (p) .....11,5 MPa
Max. permissible pressure (p max) ...17 MPa
Max. inow pressure (p in max) ... 0.8 MPa
Max. inow temperature (T in max) ..40 °C
Pumping rate, water (Q)...............330 l/h
Max. pumping rate, water
(Q max) ..................................... 500 l/h
Sound pressure level
(LpA) ..................... 81,7 dB(A); KpA= 3 dB
Sound power level (LWA)
measured ...... 94,3 dB(A); KWA= 2,35 dB
guaranteed .......................... 97 dB (A)
Vibration (ah) .....< 2.5 m/s2; K=0.15 m/s²
The values for noise and vibration were
determined according to
EN 60335-2-79:2012.
Do not exceed the maximum permitted
network impedance of 0.450Ohms at the
electrical connection point.
The user must ensure that the device is oper-
ated only on a power supply network that
fulls this requirement.
If necessary, the local power supply compa-
ny can be asked for the system impedance.
The stated vibration emission value was
measured in accordance with a standard
testing procedure and may be used to com-
pare one power tool to another.
The stated vibration emission value may
also be used for a preliminary exposure
assessment.
Warning: The vibration emission
value may differ during actual use
of the power tool from the stated
value depending on the manner in
which the power tool is used.
Try to keep the exposure to vibra-
tions as low as possible. Examples
of measures to reduce vibration
exposure are the wearing of gloves
when using the tool and limiting the
working hours. For this purpose all
parts of the operating cycle have to
be considered (for example, times
when the electric tool is switched off
and times when it is switched on but
running without any load).
Notes on Safety
This section is concerned with the basic
safety rules when working with the pres-
sure cleaner.
Explanation of symbols
Attention!
Before beginning work, familiarise
yourself thoroughly with all the op-
erating elements, particularly with
how they function and operate. Ask
a specialist if necessary.
Attention: Remove the plug from the
socket as soon as the power lead is
damaged or cut.
Also disconnect the plug from the
socket when connecting to the water
supply or trying to eliminate leaks.
The pressure cleaner is not suitable
for direct connection to the drinking
water supply system.
Safety class II (Double insulation)
Electric appliances should not be dis-
posed of in the domestic garbage.
Operate the equipment only in
an upright and never in a re-
clined position.
CAUTION. pressure cleaners
can be dangerous if they are
not operated correctly! The
21


Need help? Post your question in this forum.

Forumrules
1

Forum

parkside-phd-170-b2---ian-346400

Reset search

  • Parkside 170 Phd b2 ait 1= 3 adet Yag keçesi 2= 3 Adet Su Contasi 3= 3 Adet Sibop ihtiyacim var. Acil temin etmem gerek. Submitted on 11-3-2022 at 12:58

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside PHD 170 B2 - IAN 346400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside PHD 170 B2 - IAN 346400 in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 2,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Parkside PHD 170 B2 - IAN 346400

Parkside PHD 170 B2 - IAN 346400 User Manual - German - 22 pages

Parkside PHD 170 B2 - IAN 346400 User Manual - Dutch - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info