744068
42
Zoom out
Zoom in
Previous page
1/60
Next page
The walls in the immediate vicinity of
stationary workplaces may not have a light
color or a sheen. Windows up to head
height are to be protected against radiation
passing through them or reflecting off them,
for example by coating them with a suitable
paint.
4. Symbols and technical data
EN 60974-6 European standard for arc
welding sets and welding
power supplies with limited
on time (part 6).
Symbol for welding power
supplies which are suitable
for welding in
environments with
increased electrical
danger.
~ 50 Hz Alternating current and
rated frequency value [Hz]
U
0
Rated idling voltage [V]
40A/19.6V - 80 A/21.2 V
Maximum welding current
and the corresponding
standardized operating
voltage [A/V]
Ø Electrode diameter [mm]
I
2
Welding current [A]
t
w
Average load time [s]
t
r
Average reset time [s]
Line input; number of
phases, the alternating
current symbol and the
rated frequency value
Do not store or use the
equipment in wet or damp
conditions or in the rain.
Use the equipment only
indoors.
U
1
Line voltage [V]
I
1max
Highest rated value of the
line current [A]
I
1eff
Effective value of the
highest line current [A]
IP 21S Protection type
H Insulation class
Electrode holder
connection
Ground terminal
connection
Mains connection: 230 V ~ 50 Hz
Welding current (A) at cos ϕ= 0.73: 40 - 80
ø (mm) 1.6 2.0 2.5
I
2
40 55 80
t
w
(s) 217 116 64
t
r
(s) 1450 1381 1351
Idling voltage (V): 48
Power input: 4 kVA at 80 A cos ϕ = 0.73
Fuse (A): 16
Weight: 10.6 kg
The welding times apply for an ambient
temperature of 40° C.
S
GB/
MT
42
1~ 50 Hz
Anleitung_1549055_LB5:_ 29.10.2010 12:19 Uhr Seite 42
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside PESG 120 A1 IAN 61096 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside PESG 120 A1 IAN 61096 in the language / languages: English, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Parkside PESG 120 A1 IAN 61096

Parkside PESG 120 A1 IAN 61096 Usermanual and installation guide - German, Dutch, French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info