595416
24
Zoom out
Zoom in
Previous page
1/29
Next page
20
PDSP 1000 B2
GB
Use only materials that are suited for use in the
compressed air sandblaster gun . Do not
use quartz sand. This can lead to a dangerous
build-up of silicosis-inducing dust.
Take steps to ensure that others are not incon-
venienced (dust formation).
Ensure that the blasting medium is collected so
that it can be disposed of in an environmentally
friendly manner.
Do not remove any type plates. These contain
important information for the safe operation of
the appliance.
If you are inexperienced with the appliance,
seek training in how to use it safely.
WARNING! TOXIC DUST!
Working with harmful/toxic dusts results in
health hazards for the person operating the
appliance and for other persons in the area.
Operation
Connecting the compressed air supply
NOTE
The compressed air sandblaster gun may
only be operated on cleaned, condensate-
and oil-free compressed air and may not
exceed the maximum operating pressure of
6.3 bar at the appliance.
To ensure that you can regulate the air pres-
sure, the compressed air source should be
equipped with a (fi lter) pressure reducer.
Connect the compressed air sandblaster gun
to a suitable compressed air source by attaching
the quick-connect coupling of the supply hose to
the nipple on the sandblaster gun .
The connection locks automatically.
NOTE
Ensure that the control dial is set to "0"
before connecting the appliance to the com-
pressed air source.
Filling the blasting medium container
CAUTION!
Before you open the screw cap on the
blasting medium container , or make any
other settings, the connection to the com-
pressed air hose must be disconnected and
all pressure completely discharged.
Use only suitable blasting medium for your
sandblasting work.
NOTE
We recommend using a blasting medium
(ground blast furnace slag) with a grain size
of 0.2 mm–0.8 mm and which has been
shown not to cause silicosis.
Please ensure that the blasting medium is
totally dry and not too coarse-grained.
NOTE
The maximum grain size is 0.8 mm!
Open the screw cap on the blasting medium
container by turning it anti-clockwise.
Fill the required amount of blasting medium
into the blasting medium container .
Ensure that you do not exceed the maximum fi ll
level for the container of 900 ml.
Afterwards, close the screw cap on the blast-
ing medium container
by turning it clockwise.
NOTE REGARDING THE GRAIN SIZE OF
THE BLASTING MEDIUM
The larger/coarser the grain size of the blasting
medium used, the coarser the dirt that can be
removed using it. The supplied material, on
the other hand, is fi ne and thus more suitable
for the removal of items such as paint or rust
lm. The fi ne material also causes less dam-
age to the surfaces being treated, meaning a
choice can be made regarding these.
For coarse rust, for example, it is best to use
a coarse-grained blasting medium which you
can order online (see Chapter "Importer") or
in any good specialist retailer. Please observe
the guidelines regarding maximum grain size.
IB_43089_PDSP1000B2_LB1.indb 20IB_43089_PDSP1000B2_LB1.indb 20 28.05.14 08:5928.05.14 08:59
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside PDSP 1000 B2 - IAN 43089 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside PDSP 1000 B2 - IAN 43089 in the language / languages: English, German, Dutch as an attachment in your email.

The manual is 3,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Parkside PDSP 1000 B2 - IAN 43089

Parkside PDSP 1000 B2 - IAN 43089 User Manual - French - 29 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info