General safety instructions for air tools
Protect hoses from kinks, constrictions, solvents
and sharp edges. Keep hoses away from heat,
oil and rotating parts.
Ensure that the hose clamps are always firmly
secured. Hose clamps that have been insuffi-
ciently tightened or damaged could allow air
to escape in an uncontrolled manner.
Replace damaged hoses immediately. A dam-
aged supply line may result in the air hose flap-
ping about and may result in injuries.
If the mains power cable of the device is dam-
aged, it has to be replaced by the manufacturer
or its service department or a similarly qualified
person in order to avoid hazards.
Do not use the device when tired or under the
influence of drugs, alcohol or medications.
One moment of carelessness when using the
device may result in serious injuries.
Do not directly inhale the exhaust air. Keep
eyes away from exhaust air. Exhaust air from
the compressed air device may contain water,
oil, metal particles or contamination from inside
the compressor. This may result in injury to health.
BE CAREFUL WHEN YOU
PUT DOWN THE DEVICE! Always put down
the device so it does not come into contact with
the trigger. This could potentially result in acci-
dental activation of the device, which again
could result in hazards.
Only use suitable accessories. These may be
purchased from the manufacturer. Using non-
OEM accessories may result in hazards.
Only use filtered and regulated compressed
air. Dust, caustic vapours and/or moisture may
damage the motor of an air tool.
The hose must be designed for pres-
sures of at least 8.6 bar or 125 PSI,
but at least 150 % of the maximum
pressure generated in the system.
The tool and supply line must be
equipped with a hose coupling to
completely remove pressure when
disconnecting the coupling hose.
DANGER! Avoid contact with live lines. This
device is not insulated against electric shock.
DANGER OF INJURY! High
working pressures can give rise to recoil forces
that under certain conditions can result in danger
from continuous loading.
If you are inexperienced in the use of this type
of device, you should seek out information or
training to learn how to handle it safely.
DANGER OF STAB
WOUNDS! Do not treat an injection as a sim-
ple cut. A high pressure jet may inject toxins into
the body and cause serious injuries. If the spray
is injected into the skin, seek medical help im-
mediately.
Do not modify this device in any way without
the manufacturer‘s approval.
Only use the device with the specified pressure
(2–9 bar).
Disconnect the tool from the air supply after
each use and when not in use.
Discontinue use if the tool leaks or is in need of
repair.
Never connect the tool to an air hose with
pressure exceeding 9 bar.
Keep your working area clean and well lit.
Untidy or poorly lit working areas can lead to
accidents. Doing so will allow you better con-
trol of the device, particularly under unforeseen
circumstances.
Only have the device repaired
by qualified specialist personnel using OEM
spare parts. This will ensure that your device
remains safe to use.
Keep children and other individuals away from
the device during use. Distractions can cause
you to lose control of the device.
Wear suitable clothing. Do not wear loose
clothing or jewellery. Keep your hair, clothing
and gloves clear of moving parts. Loose cloth-
ing, jewellery or long hair can become trapped
in moving parts.
Put down trigger and device in the event of un-
expected compressor failure.
If possible, use a condensate trap or drain the
hoses and pipes of condensate (water) regu-
larly before and during the use compressed air
devices (water).
ATTENTION! An undersized com-
pressed air system may minimise the
efficiency of your device.
89574_par_Druckluft Wasserstrahler PDWS 8 A1_Content_LB2 (ohne NL).indd 24 11.04.13 16:47
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside IAN 89574 PDWS 8 A1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside IAN 89574 PDWS 8 A1 in the language / languages: French as an attachment in your email.

The manual is 1,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Parkside IAN 89574 PDWS 8 A1

Parkside IAN 89574 PDWS 8 A1 User Manual - English, German, Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info