744904
39
Zoom out
Zoom in
Previous page
1/54
Next page
39 GB/MT
and advice. Electrical power tools are dan-
gerous when they are used by inexperienced
people.
e)
Look after the device carefully. Check
that moving parts are working prop-
erly and move freely. Check for any
parts that are broken or damaged
enough to detrimentally affect the
functioning of the device. Have dam-
aged parts repaired before you use
the device. Many accidents have their origins
in poorly maintained electrical power tools.
f) Use the electrical power tool, accesso-
ries, inserted tools etc. in accordance
with these instructions and advice, and
the stipulations drawn up for this par-
ticular type of device. In doing this, take
into account the working conditions
and the task in hand. The use of electrical
power tools for purposes other than those in-
tended can lead to dangerous situations.
Additional safety advice
for paint spray guns
The spray gun must never be used for
spraying inflammable substances.
Spray guns must never be cleaned
using inflammable solvents.
If you do not know the level of danger
a substance presents, do not spray it.
Precise observation of the hazard
warnings, information and data
sheets available from the sprayed
medium manufacturer is essential.
Wear a breathing / dust mask!
The inhalation of paint mist and sol-
vent vapour is hazardous to health.
Work in adequately ventilated
spaces only.
Wear protective glasses!
Never aim the spray at living
creatures.
DANGER OF EXPLOSION! Do
not use the device in environments
containing gases, open flames, fires
or gas-operated water heaters.
NO SMOKING!
Paint and solvents (thinners) must
have a flashpoint above 21°C.
Advice on use
DIN-sec / Viscosity
The Parkside paint spray gun PFS 100 B2 can be
used to apply sprayed media with a viscosity up to
80 DIN-sec. Viscosity is determined in a simplified
measuring procedure using the supplied measuring
cup (see Fig. C).
1. Immerse and fill the supplied measuring cup
12
to the top with the medium to be sprayed.
2. Lift the measuring cup
12
out of the medium
to be sprayed and let the liquid flow out (see
Figure C).
3. Measure the time in seconds it takes for the
flow of liquid out of the measuring cup to cease.
This time is the “DIN-seconds (DIN-s)” value of
viscosity.
4. If the value is too high, incrementally add and
mix in small quantities of a thinner compatible
with the medium to be sprayed. Proceed in ac-
cordance with the section about “Preparing the
sprayed medium”.
5. Remeasure the DIN-seconds value.
Repeat this procedure until a value is obtained
that complies with the values in the table.
Preparing the sprayed medium
NOTE: Most paints, varnishes etc. in the shops
are intended to be applied by brush not spray. To
achieve the best spraying result, you should prepare
your paint or varnish etc. in accordance with DIN
guidelines to achieve a suitable viscosity (see table).
General safety advice for electrical power tools / Advice on use
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside IAN 63964 PFS 100 B2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside IAN 63964 PFS 100 B2 in the language / languages: English, Portuguese, Spanish as an attachment in your email.

The manual is 0,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Parkside IAN 63964 PFS 100 B2

Parkside IAN 63964 PFS 100 B2 User Manual - German, Dutch, French, Italian - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info