745193
31
Zoom out
Zoom in
Previous page
1/34
Next page
31 GB
Preparing to weld / Welding / Overheat protection / Maintenance
Safety information / Assembling the welding shield / Preparing to weld
light beam emitted by the arc, yet allows for a
clear view of the work piece.
Welding
After making all the electrical connections for the
power supply and for the welding circuit, proceed
as follows:
Insert the uncoated end of the electrode into
the electrode holder
6
and connect the earth
terminal
4
to the work piece. Be sure the
electrical contact is good.
Switch on the equipment by setting the ON/
OFF switch
2
to the „ON“ position.
Adjust the welding current according to the
electrode being used using the hand wheel
3
.
Hold the welding shield
8
in front of your
face and guide the tip of the electrode over the
work piece as if trying to light a match. This is
the best method for sparking the arc.
Use a test piece to check if you selected the
correct electrode and current.
ATTENTION!
Do not dab the work piece with the electrode. It
could become damaged and make it more difficult
to spark the arc. Once the arc is sparked, try to
maintain a distance to the work piece appropriate
for the selected electrode diameter. Keep the dis-
tance as consistent as possible whilst welding. The
electrode grade in the work flow direction should
be 20 - 30 degrees.
ATTENTION!
Always use forceps to dispose of used electrodes
or move hot work pieces. Please remember to al-
ways place the electrode holder onto an insulating
pad after welding.
Only remove slag once the seam has cooled. If
continuing to weld on an interrupted weld seam,
first remove the slag at the start of weld.
ATTENTION!
Welding produces heat. The welding equipment
must therefore be operated in open loop after use
for at least half an hour. Or alternatively allow the
equipment to cool off for one hour. Only pack up
and store the equipment once the equipment tem-
perature has normalised.
Switch the equipment off by setting the ON /
OFF switch
2
to the „OFF“ position.
Overheat protection
The welding equipment features overheat protec-
tion. If the overheat protection is triggered, the
control light
7
will light up. Allow the welding
equipment to cool down for a while.
PESG 120 A1 (with AC 230 V 50 Hz power plug):
The supply line fuses to the mains sockets must
meet the requirements (VDE 0100). Earthed wall
sockets must be protected with max. 16 A (model
and technical data: NDM1-63, AC 230 / 400 V
C16. IEC 60898.time lag. Manufacturer: Nader)
(fuses or line circuit breaker). Higher fuse ratings
can result in burnt wires or fire damage to the
building.
Attention: The equipment must be connected to
a mains source with the fuse rating specified
above. If the electrode holder and earth terminal is
short circuited, the fuse can be triggered in
16-20 seconds.
Classification per EMV standard: Class A per IEC
60974-10
Warning: Equipment categorised Class A are
intended for industrial use. When used in other
areas, electromagnetic tolerance may not be war-
ranted or failures may occur.
Maintenance
Regularly clean dust and dirt off the equipment.
Clean the equipment with a fine brush or a dry
cloth.
55732_Elektro-Schweissgeraet_content_AT-NL.indd 31 21.11.13 14:51
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside IAN 55732 PESG 120 A1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside IAN 55732 PESG 120 A1 in the language / languages: English, German, Dutch as an attachment in your email.

The manual is 1,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Parkside IAN 55732 PESG 120 A1

Parkside IAN 55732 PESG 120 A1 User Manual - French - 34 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info