PHDB 4 B2
20 
GB
IE
PETROL PRESSURE WASHER PHDB 4 B2
Introduction
Congratulations on the purchase of your new appliance. You have chosen
a high-quality product. The operating instructions are a part of this product.
They contain important information about safety, usage and disposal.
Before using the product, please familiarise yourself with all operating and
safety instructions. Use the product only as described and for the range of
applications specified. Please also pass these operating instructions on to
any future owner.
Intended use
This appliance is designed for cleaning:
machines, vehicles, buildings, tools, façades, terraces, garden equipment,
etc.
for low-pressure cleaning with a cleaning agent (e.g. cleaning machines,
vehicles, buildings, tools),
for high-pressure cleaning without a cleaning agent (e.g. cleaning
façades, terraces, garden equipment).
Self-priming when using alternative water sources
This appliance is self-priming and allows the suction of water from containers
and natural sources. It is IMPORTANT that the filter on the water inlet is
cleaned and in place, and that only clean water is sucked in.
Any other use that is not expressly permitted in these operating instructions
may damage the appliance and represents a serious risk for the user.
Please make sure that you pay attention to the restrictions in the safety
instructions. Pay attention to the national regulations which may restrict the
use of the machine.
Any other uses of or modifications to the machine are deemed to be
improper usage and may result in serious physical injury.
Not intended for commercial use.
DANGER!
Risk of injury! When using at petrol filling stations or other danger
areas, comply with all corresponding safety regulations.
NOTE
Waster water that is contaminated with oil should not be released
into the soil, open water or down drains. Therefore, only wash engines
and vehicle underbodies at suitable sites that have oil separators.
CAUTION! Water quality requirements:
Only clean water may be used as a high-pressure medium. Contam-
ination can lead to premature wear or residues in the appliance. If re-
cycling water is used, the following thresholds may not be exceeded.
pH value 6.5...9.5
Electrical conductivity* Conductivity
Fresh water
+1200 S/cm
Settleable solids** < 0.5 mg/l
Filterable substances*** < 50 mg/l
Hydrocarbons < 20 mg/l
Chloride < 300 mg/l
Sulphate < 240 mg/l
Calcium < 200 mg/l
Overall hardness < 28 °dH
< 50 °TH
< 500 ppm
(mg CaCO
3
/l)
Iron < 0.5 mg/l
Manganese < 0.05 mg/l
Copper < 2 mg/l
Active chlorine < 0.3 mg/l
Free of unpleasant odours
*Maximum in total 2000 S/cm
**Sample volume 1 l, sedimentation time 30 min
***No abrasive substances
Residual risks
CAUTION!
Even if used correctly, it is not possible to exclude non-apparent
residual risks entirely.
Injuries due to slipping on waste water.
Injuries or property damage due to the high-pressure water jet.
Features
High-pressure hose
Quick connector
Hose holder
Nozzles (red, yellow, green, white, black)
Air filter
Filler cap
Fuel tank
Tubular frame
Filler cap for cleaning agent tank
Cleaning agent tank
Cleaning agent hose
Rubber feet
Lower spray gun holder
Tyres
Oil drain screw
Jet pipe
Pull starter
Hand spray gun
Upper spray gun holder
Trigger
Trigger lock
Exhaust silencer
Wing nut
Choke
Fuel tap
Spark plug/Spark plug connector
Carburettor
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside IAN 291647 PHDB 4 B2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside IAN 291647 PHDB 4 B2 in the language / languages: English, German, Dutch, French, Portuguese, Spanish as an attachment in your email.

The manual is 1,97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info