745924
19
Zoom out
Zoom in
Previous page
1/99
Next page
PSTDA 20-Li A1
GB
IE 15
Noise emission value:
Noise measurement value determined in accor-
dance with EN 60745. The A-rated noise level of
the power tool is typically as follows:
Sound pressure level: L
PA
= 80dB (A)
Uncertainty K: K
PA
= 3 dB
Sound power level: L
WA
= 91 dB (A)
Uncertainty K: K
WA
= 3 dB
Wear hearing protection!
Total vibration value:
(vector total of three directions) determined in
accordance with EN 60745:
Cutting boards: a
h,B
= 5.9 m/s
2
Uncertainty K = 1.5 m/s
2
Cutting sheet metal: a
h,M
= 7.2 m/s
2
Uncertainty K = 1.5 m/s
2
NOTE
The vibration level specified in these instruc-
tions has been measured in accordance
with the standardised measuring procedure
specified in EN 60745 and can be used to
make equipment comparisons. The specified
vibration emission value can also be used to
make an initial exposure estimate.
WARNING!
The vibration level will vary according to the
use of the power tool and may sometimes
be higher than the value specified in these
instructions. Regular use of the power tool in
this way may cause the user to underestimate
the vibration. Try to keep the vibration loads
as low as possible. Measures to reduce the
vibration load are, e.g. wearing gloves and
limiting the working time. Wherein all states
of operation must be included (e.g. times
when the power tool is switched off and times
where the power tool is switched on but run-
ning without load).
General Power
Tool Safety Warnings
WARNING!
Read all safety warnings and all instructions.
Failure to follow the warnings and instruc-
tions may result in electric shock, fire and/or
serious injury.
Save all warnings and instructions for future
reference.
The term "power tool" in the warnings refers to your
mains-operated (corded) power tool or battery-
operated (cordless) power tool.
1. Work area safety
a) Keep work area clean and well lit. Cluttered
or dark areas invite accidents.
b) Do not operate power tools in explosive atmo-
spheres, such as in the presence of flammable
liquids, gases or dust. Power tools create sparks
which may ignite the dust or fumes.
c) Keep children and bystanders away while
operating a power tool. Distractions can cause
you to lose control.
2. Electrical safety
a) Power tool plugs must match the outlet.
Never modify the plug in any way.
Do not use any adapter plugs with earthed
(grounded) power tools. Unmodified plugs
and matching outlets will reduce risk of electric
shock.
b) Avoid body contact with earthed or grounded
surfaces, such as pipes, radiators, ranges and
refrigerators. There is an increased risk of elec-
tric shock if your body is earthed or grounded.
c) Do not expose power tools to rain or wet
conditions. Water entering a power tool will
increase the risk of electric shock.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside IAN 281995 PSTDA 20Li A1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside IAN 281995 PSTDA 20Li A1 in the language / languages: English, German, Dutch, French, Portuguese, Spanish as an attachment in your email.

The manual is 1,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info