General safety rules General safety rules / Before use / Start-up
because the risk from vibration is generally gr
eater
when the grip force is higher.
Additional safety instructions
for pneumatic power tools
Air under pressure can cause severe injury:
always shut off air supply, drain hose of air
pressure and disconnect tool from air supply
when not in use, before changing accessories
or when making repairs;
never direct air at yourself or anyone else.
Whipping hoses can cause severe injury. Always
check for damaged or loose hoses and fittings.
Cold air shall be directed away from hands.
Whenever universal twist couplings (claw cou-
plings) are used, lock pins shall be installed
and whipcheck safety cables shall be used
to safeguard against possible hose-to-tool or
hose-to-hose connection failure.
Do not exceed the maximum air pressure stated
on the tool.
Never carry an air tool by the hose.
General safety
instructions for compressed
air metal shears
Always wear safety gloves.
Be careful whilst working with the shears. Edges
created on the work piece can cause cuts.
If possible, already run the shears at full speed
when applying them. Otherwise sudden, jerky
movement could result if the shears catch when
starting up at the front, resulting in backlash.
Before use
Installation
The device itself is fully functional at delivery. You
will need to install a coupler before using the de-
vice itself (please note the data specified under
technical details for accuracy of fit/size).
Wrap the coupler with Teflon tape (not included)
before screwing it into the compressed air unitn.
Wrap the tape as tightly as possible around
the thread. This will minimise the likelihood of
air leaking and optimise the work process.
Now screw the coupling into the compressed
air equipment.
Tighten the coupler into the compressed air unit
with a size 14 spanner using moderate force
(see Fig. A).
Adjusting the compressed air supply and
connections
Only use filtered, lubricated and regulated com-
pressed air.
Apply the connection method on the compressed
air unit shown in Fig. B. This will increase the ef-
fectiveness and life of the tool.
Set your compressor to the device‘s operating
pressure specified under Technical Data. Please
note, on average the pressure for 10 m of hose
will decrease by about 0.5 bar.
Excessive pressure is dan-
gerous! Never exceed the specified pressure!
Add a few drops of oil for compressed air tools
or SAE 10–20 motor oil to the compressed air
c
onnection of the compressed air unit. Using othe
r
oil (esp. viscous) will result in malfunctions, dam-
age or even total loss of the device.
Start-up
Connecting the
compressed air tool
Verify the work piece is properly secured.
Connect the compressed air by pushing on the
coupler of the hose with some force (see Fig. C).
Verify the air hose is properly seated (see Fig. D).
A loose hose whipping about out of control pre-
sents a major hazard. The coupler must be tightly
seated for the same reason. Also check this.
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside IAN 275681 PDBS 6.2 A1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside IAN 275681 PDBS 6.2 A1 in the language / languages: French as an attachment in your email.

The manual is 1,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Parkside IAN 275681 PDBS 6.2 A1

Parkside IAN 275681 PDBS 6.2 A1 User Manual - English, German, Dutch - 39 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info