Additional safety instructions
Connect the appliance only to a power
socket with a residual current circuit
breaker of rated residual current no
more than 30 mA.
Keep power cords and extension cords
away from the disc. If they are damaged
or cut through, immediately pull the plug
from the outlet. Do not touch the cable
before it has been disconnected from the
power supply. Risk of electric shock!
The replacement of the plug or the con-
nection line must always be executed
by the manufacturer of the electric tool
or his/her customer service in order to
avoid any hazards.
Only use grinding discs where the in-
dicated rotational speed is at least as
high as what has been specied on the
name plate of the device.
Carry out a visual inspection of the
grinding disc before use. Do not use
any damaged or deformed grinding
discs. Replace any damaged or worn
grinding discs.
Make sure that the sparks produced by
grinding do not present a danger, e.g.
reach people or ignite ammable subs-
tances.
Always wear safety goggles, safety
gloves, respiratory protection and ear
protection when grinding, brushing and
cutting.
Never keep the ngers between the
grinding disc and spark protection or in
close proximity to the protective hoods.
There is a risk of crushing.
The rotating parts of the device cannot
be covered due to functional reasons.
Therefore, proceed cautiously and hold
the workpiece rmly in order to avoid
slipping which could cause your hands to
come into contact with the grinding disc.
The workpiece gets hot during grin-
ding. Do not touch the machined area,
allow it to cool down. There is a risk of
burning. Do not use coolants or the like.
If you are tired or have consumed al-
cohol or tablets, do not work with the
device. Always have a break on time.
Switch the device off and remove the
mains plug
- to loosen a blocked insertion tool,
- if the connection line is damaged or
entangled,
- in case of unusual sounds.
RESIDUAL RISKS
Even if properly operating and handling
this electric tool, some residual risks will
remain. Due to its construction and build,
this electric tool may present the following
hazards:
a) Lung damage if suitable respiratory pro-
tection is not worn.
b) Hearing damage if suitable ear protec-
tion is not worn.
c) Damage to health due to
- touching the area of the grinding tool
which is not covered;
- ejection of parts of workpieces or
damaged grinding discs.
d) Health injuries which result from swin-
ging hand and arm, in the event that
the device is used over a longer period
of time or is not used and maintained
properly.
Warning! During operation, this
electric tool generates an electro-
magnetic eld which, under certain
circumstances, may impair the func-
tionality of active or passive medical
implants. To reduce the risk of seri-
ous or lethal injuries, we recommend
that persons with medical implants
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside IAN 275389 PWS 125 C3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside IAN 275389 PWS 125 C3 in the language / languages: English, German, Dutch, Danish as an attachment in your email.

The manual is 4,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Parkside IAN 275389 PWS 125 C3

Parkside IAN 275389 PWS 125 C3 User Manual - French - 70 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info