672275
7
Zoom out
Zoom in
Previous page
1/76
Next page
U-5~18MX4 + U-8~16ME4M + U-8~16ME4 + U-4~6ML5
Urban Multi air conditioner
4PW40727-1A
Operation manual
5
7.4. Setting the master remote controller
When the system is installed as shown in figure 9 (MX4 + ML5 – the
outdoor unit is connected to several indoor units) and figure 10
(
ME4
one HR unit is connected to several indoor units), it is
necessary to designate one of the remote controllers as the master
remote controller.
Only the master remote controller can select heating or cooling
and in case of ME4 units, automatic operation.
The displays of slave remote controllers show (change-
over under centralized control) and slave remote controllers
automatically follow the operation mode directed by the master
remote controller.
However, it is possible to changeover to program dry with slave
remote controllers if the system is in cooling operation set by the
master remote controller.
How to designate the master remote controller
1 Press the operation mode selector button of the current master
remote controller for 4 seconds.
The display showing (change-over under centralized
control) of all slave remote controllers connected to the same
outdoor unit or HR unit flash.
2 Press the operation mode selector button of the controller that
you wish to designate as the master remote controller. Then
designation is completed. This remote controller is designated
as the master remote controller and the display showing
(change-over under centralized control) vanishes.
The displays of other remote controllers show (change-
over under centralized control).
7.5. Precautions for group control system or two
remote controller control system
This system provides two other control systems beside individual
control (one remote controller controls one indoor unit) system.
Confirm the following if your unit is of the following control system
type.
Group control system
One remote controller controls up to 16 indoor units. All indoor
units are equally set.
Two remote controller control system
Two remote controllers control one indoor unit (in case of group
control system, one group of indoor units). The unit is
individually operated.
8. ENERGY SAVING AND OPTIMUM
OPERATION
Observe the following precautions to ensure the system operates
properly.
Adjust the air outlet properly and avoid direct air flow to room
inhabitants.
Adjust the room temperature properly for a comfortable
environment. Avoid excessive heating or cooling.
Prevent direct sunlight from entering a room during cooling
operation by using curtains or blinds.
Ventilate often.
Extended use requires special attention to ventilation.
Keep doors and windows closed. If the doors and windows
remain open, air will flow out of your room causing a decrease in
the cooling or heating effect.
Be careful not to cool or heat too much. To save energy, keep
the temperature setting at a moderate level.
Never place objects near the air inlet or the air outlet of the unit.
It may cause deterioration in the effect or stop the operation.
Tu rn off the main power supply switch to the unit when the unit is
not used for longer periods of time. If the switch is on, it uses
electricity. Before restarting the unit, turn on the main power
supply switch 6 hours before operation to ensure smooth
running. (Refer to "Maintenance" in the indoor unit manual.)
When the display shows (time to clean the air filter), ask a
qualified service person to clean the filters. (Refer to
"Maintenance" in the indoor unit manual.)
Keep the indoor unit and remote control at least 1 m away from
televisions, radios, stereos, and other similar equipment.
Failing to do so may cause static or distorted pictures.
Do not place items under the indoor unit which may be damaged
by water.
Condensation may form if the humidity is above 80% or if the
drain outlet gets blocked.
9. MAINTENANCE
9.1. Maintenance after a long stop period (e.g. at the
beginning of the season)
Check and remove everything that might be blocking inlet and
outlet vents of indoor units and outdoor units.
Clean air filters and casings of indoor units. Refer to the
operation manual supplied with the indoor units for details on
how to proceed and make sure to install cleaned air filters back
in the same position.
Tu rn on the power at least 6 hours before operating the unit in
order to ensure smoother operation. As soon as the power is
turned on, the remote controller displays appear.
NOTE
Contact your dealer in case of changing the
combination or setting of group control and two remote
controller control systems.
Recommended temperature setting
For cooling 26~28°C
For heating 20~24°C
Pay attention to the fan.
It is dangerous to inspect the unit while the fan is running.
Be sure to turn off the main switch and to remove the fuses
from the control circuit located in the outdoor unit.
4PW40727-1A Page 5 Thursday, October 11, 2007 11:02 AM
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Panasonic U-14ME4xM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Panasonic U-14ME4xM in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info