35
RS232C
This sets the communication parameters at the
serial terminals.
For details on the serial terminals, refer to “Using
the serial terminals” (page 38).
IN BAUDRATE : 9 600, 19 200 or 38 400 is
selected.
IN PARITY : NONE, EVEN or ODD is
selected.
OUT BAUDRATE: 9 600, 19 200 or 38 400 is
selected.
OUT PARITY : NONE, EVEN or ODD is
selected.
VPS SYSTEM : MASTER or SLAVE is
selected.
GROUP : A to Z is selected. MASTER
or SLAVE is also selected.
SYSTEM INFORMATION
The projector’s system information can be viewed.
FAN CONTROL1
The fan can be controlled in accordance with the
operating conditions.
NORMAL : Standard setting
HIGHLAND : This is selected when using the
projector at an altitude of over
1 400 meters.
FAN CONTROL2
The fan can be controlled in accordance with the
direction in which the images are to be projected.
HORIZ. : Standard setting
VERTICAL : This is selected when projecting
images at a significant angle toward
the vertical (more than 30 degrees
from the horizontal).
FUNC 1
The user can set the function for the remote
control’s FUNC1 button.
LAMP POW : The button functions in the same
way as “LAMP POWER” of
“OPTION2”.
ASPECT : The button functions in the same
way as “ASPECT” of “POSITION”.
AUTO POW.OFF
The projector can be automatically set to the
standby mode if no signals are input for the set
duration.
DISABLE : Standard setting. This function
is set to OFF.
15MIN.–60MIN.: The duration can be set in 5-
minute increments from 15 to
60 minutes.
PASSWORD
This function is used when a service person.
Input the password with the numeric buttons (0 to
9) of the remote control and press ENTER button to
confirm the entry.
• The auto power OFF function does not
work while the freeze function is used.
Note
H: HORIZ.
V: VERTICAL
• Select the correct FAN CONTROL2
setting in accordance with the direction
in which the images are to be projected.
Using the projector at the wrong FAN
CONTROL2 setting will shorten the
service life of the lamps.
Attention