6. Troubleshooting
6. 1. Summary of shut down system
Value "**" is changed by "Lamp mode", or "Fan mode" and "Setting attitude"
Connection problem with Intake air
temperature sensor.
Faulty temperature sensor.
Lamp unit cover is not installed.
Blown out of the fuse
(with some reason)
Iris unit abnormal
Iris drive circuit abnormal
Communication line is disconnection
in A-P.C.Board.
Connector is disconnected
Fan abnormal
Fan speed abnormal
Over 3800 hours
=> “Replace lamp"
Lamp hours
=> Over 4000 hours
(Shouts down after 10
minutes.)
Intake air temperature error
High temperature of environment
Intake air window is closed
Exhausting air temperature error:
Closed ventilator
High altitude mode is not on.
Lamp usage hour is over the guideline.
Lamp status
=> Lamp is off during the status
other than normal one
Intake air temperature sensor:
=> More than 43 degrees C
"Air filter cleaning"
When the abnormality of the lamp and the abnormality of the fan occurred, possess a shut down function to make a
standby state for safety promptly.
Monitor LED indication OSD Warning Indication
Presumed Factor
Blown out of the fuse
(with some reason)
Power fuse
=> 8A 250V
Shut down Detection
LAMP LED Lights
Intake air temperature sensor:
=> Under -36 degrees C
Exhaust air temperature
sensor:
=> More than 79 degrees C
Filter air temperature
sensor:
=> More than threshold
** degrees C
Exhaust air temperature
sensor:
=> Under -36 degrees C
LAMP indicator
Flashing red
TEMP indicator
Flashing red
No FAN sense signal
Each FAN sense signal:
=> Rotation speed is slower
than 50% of target for
more than 10 seconds.
All indicator Illuminating
Interlock SW
=> Abnormal :OFF
No flashing or blinking
Thermal fuse
=> More than 105 degrees C
IRIS sense signal
=> Unresponsiveness is more
than 1 minute
IIC bus
=>FPGA initialized error
=>Communication error
Failed lamp ON,
lamp abnormal condition
Ballast block faulty,
Hot restart
Connection problem with Exhausting air
temperature sensor.
Faulty temperature sensor.
Filter clogging
Closed Intake
High altitude mode is not on
More than 41 degrees C
=>“TEMPERATURE WARNING"
lower than 39 degrees C
=> Warring cancel
More than 77 degrees C
=>“TEMPERATURE WARNING"
lower than 75 degrees C
=> Warring cancel
INF - 15
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Panasonic PT-AT6000E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Panasonic PT-AT6000E in the language / languages: English as an attachment in your email.

The manual is 38,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Panasonic PT-AT6000E

Panasonic PT-AT6000E User Manual - German - 110 pages

Panasonic PT-AT6000E User Manual - Spanish - 110 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info