526902
10
Zoom out
Zoom in
Previous page
1/92
Next page
10
TROUBLESHOOTING TROUBLESHOOTING
Symptom
Symptom
Check
Check
Heating/Cooling operation is not working
ef ciently.
Set the temperature correctly.
Close all doors and windows.
Clear any obstruction at the air inlet and air outlet vents.
Noisy during operation. Check if the unit has been installed at an incline.
The unit does not work. Check if the circuit breaker is tripped.
Check if timers have been set.
Symptom
Symptom
Cause
Cause
Mist emerges from indoor unit. Condensation effect due to cooling process.
Water owing sound during operation. Refrigerant ow inside the unit.
The room has a peculiar odour. This may due to damp smell emitted by the wall, carpet, furniture or
clothing.
Indoor fan stops occasionally during automatic
fan speed setting.
This helps to remove the surrounding odours.
Operation is delayed a few minutes after
restart.
The delay is a protection to the unit’s compressor.
Outdoor unit emits water/steam. • Condensation or evaporation occurs on pipes.
Timer indicator is always on. The timer setting repeats daily once set.
Power indicator blinks during operation and
the indoor fan is stopped.
The unit is in defrost mode, and the melted frost is drained from the
outdoor unit.
Indoor fan stops occasionally during heating
operation.
To avoid unintended cooling effect.
Power indicator blinks before the unit is
switched on.
This is a preliminary step in preparation for the operation when the ON
timer has been set.
Cracking sound can be heard during
operation.
Changes of temperature cause the expansion/contraction of the unit.
The following symptoms do not indicate malfunction.
The following symptoms do not indicate malfunction.
Check the following before calling for servicing.
Check the following before calling for servicing.
The following symptons occurs when abnormality occurs during operation.
The following symptons occurs when abnormality occurs during operation.
The unit stops and operation LED OFF.
OFF indicator does not shown on remote control display.
When abnormality occurs, use remote control to retrieve error code.
Ensure the operation LED is in OFF condition.
OFF
/
ON
TEMP
TIMER/CLOCK
MODE
QUIET/
POWERFUL
FAN SPEED
MODE
CHECK RESET
AIR SWING
OFF/ON
CANCELCLOCK
SET
SELECTUP
DOWN
AC RC
2
Press
UP
or
DOWN
.
If error code and
abnormality can be
identi ed, the operation
LED will be ON
continuously, then jot
down the error code.
Press for 5 seconds.
1
3
Press for 5 seconds to
quit checking.
Operation LED
OFF Indicator
4
Reveal the error code to authorized dealer.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Panasonic CS-E15JD3EA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Panasonic CS-E15JD3EA in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 3,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info