8
<Note>
The remaining battery capacity for digital batteries is displayed
as % inside the viewfinder (PRO14/TRIM14/HYTRON50/
HYTRON100/HYTRON120/DIONIC90/DIONIC160/NP-L50).
The BATT NEAR END alarm, however, is triggered according to
the setting on the <BATTERY SETTING1> screen, regardless of
the % indication.
The ____ in the Adjustable Range column indicates the preset
mode.
Items/
Data Saved
Adjustable
Range
Remarks
DIONIC90
_
Enable selection under BATTERY SELECT.
_: Enable selection.
• : Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL
: Set voltage manually.
11.0
:
13.6
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.
–CUF
DIONIC160
_
Enable selection under BATTERY SELECT.
_: Enable selection.
• : Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL
: Set voltage manually.
11.0
:
13.3
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.
–CUF
HP-90L
_
Enable selection under BATTERY SELECT.
_: Enable selection.
• : Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL
: Set voltage manually.
11.0
:
12.4
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.
–CUF
BP-H120
_
Enable selection under BATTERY SELECT.
_: Enable selection.
• : Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL
: Set voltage manually.
11.0
:
11.5
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.
–CUF
NP-L50
_
Enable selection under BATTERY SELECT.
_: Enable selection.
• : Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL
: Set voltage manually.
11.0
:
13.0
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.
–CUF
Items/
Data Saved
Adjustable
Range
Remarks
ENDURA50
_
Enable selection under BATTERY SELECT.
_: Enable selection.
• : Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL
: Set voltage manually.
11.0
:
13.1
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.
–CUF
ENDURA80
_
Enable selection under BATTERY SELECT.
_: Enable selection.
• : Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL
: Set voltage manually.
11.0
:
13.1
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.
–CUF
BP-L60/90
_
Enable selection under BATTERY SELECT.
_: Enable selection.
• : Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL
: Set voltage manually.
11.0
:
11.2
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.
–CUF
107


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Panasonic AJ-SPX 800P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Panasonic AJ-SPX 800P in the language / languages: English as an attachment in your email.

The manual is 3,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info