597958
99
Zoom out
Zoom in
Previous page
1/108
Next page
7
Chapter 7 Menu description tables
99
HYTRON120
2
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2 : The selection is enabled.
/:The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL: The voltage is set manually.
11.0
:
13.1
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
BP-H120
2
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2 : The selection is enabled.
/:The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL: The voltage is set manually.
11.0
:
11.7
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
NP-L50
2
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2 : The selection is enabled.
/:The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL: The voltage is set manually.
11.0
:
13.1
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
ENDURA50
2
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2 : The selection is enabled.
/:The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL: The voltage is set manually.
11.0
:
12.9
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
DIONIC90
2
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2 : The selection is enabled.
/:The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL: The voltage is set manually.
11.0
:
13.6
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
DIONIC160
2
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2 : The selection is enabled.
/:The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL: The voltage is set manually.
11.0
:
13.3
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
HP-90L
2
1 2
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2 : The selection is enabled.
/:The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL: The voltage is set manually.
11.0
:
12.4
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
Item/
Data storage
Variable
range
Remarks
Item/
Data storage
Variable
range
Remarks
The underlining in the variable range column indicates the setting in the preset mode.
CUF
CUF
CUF
CUF
CUF
CUF
CUF
21: Select this item for the PHD-90L manufactured by PACO.
99


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Panasonic AJ-SDC 905P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Panasonic AJ-SDC 905P in the language / languages: English as an attachment in your email.

The manual is 2,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info