93
Setting menu screens
(CAM MAIN MENU 4)
EVALUATION screen
The underlining in the variable range column indicates the setting in the preset mode.
O
S/N measurement screen
The S/N measurements are performed on this screen.
Item
Variable
range
Remarks
S/N ON
VF
display
ENG
For setting the S/N
measurement.
DETAIL ON
OFF
ENG For setting the DETAIL to
ON or OFF.
H-F COMPE. ON
OFF
ENG For setting the high-
frequency compensation
to ON or OFF.
GAMMA ON
OFF
ENG For setting the GAMMA to
ON or OFF.
MATRIX ON
OFF
ENG For setting the MATRIX to
ON or OFF.
FLARE ON
OFF
ENG For setting the FLARE to
ON or OFF.
M. PED –200
:
+140
:
+200
ENG For adjusting the master
pedestal level.
O
Resolution measurement screen
The resolution measurements are performed on
this screen.
Item
Variable
range
Remarks
RESOLUTION ON
VF
display
ENG For setting the resolution
measurement.
DETAIL ON
OFF
ENG For setting the DETAIL to
ON or OFF.
H-F COMPE. ON
OFF
ENG For setting the high-
frequency compensation
to ON or OFF.
GAMMA ON
OFF
ENG For setting the GAMMA to
ON or OFF.
MATRIX ON
OFF
ENG For setting the MATRIX to
ON or OFF.
FLARE ON
OFF
ENG For setting the FLARE to
ON or OFF.
M. PED –100
:
+18
:
+100
ENG For adjusting the master
pedestal level.
O
Sensitivity measurement screen
The sensitivity measurements are performed on
this screen.
Item
Variable
range
Remarks
SENSITIVITY ON
VF
display
ENG For setting the sensitivity
measurement.
KNEE ON
OFF
ENG For setting the KNEE to
ON or OFF.
W. CLIP ON
OFF
ENG For setting the white clip
to ON or OFF.
M. PED –100
:
+18
:
+100
ENG For adjusting the master
pedestal level.
O
Modulation measurement screen
The modulation measurements are performed on
this screen.
Item
Variable
range
Remarks
MODULATION ON
VF
display
ENG For setting the modulation
measurement.
DETAIL ON
OFF
ENG For setting the DETAIL to
ON or OFF.
H-F COMPE. ON
OFF
ENG For setting the high-
frequency compensation
to ON or OFF.
GAMMA ON
OFF
ENG For setting the GAMMA to
ON or OFF.
MATRIX ON
OFF
ENG For setting the MATRIX to
ON or OFF.
FLARE ON
OFF
ENG For setting the FLARE to
ON or OFF.
M. PED –100
:
+18
:
+100
ENG For adjusting the master
pedestal level.