597938
142
Zoom out
Zoom in
Previous page
1/152
Next page
142
Warning System
Chapter 9 Maintenance and Inspections
Warning System
Warning Description Tables
If a problem is detected immediately after the power is turned on, or during operation, this will be indicated by the
WARNING lamp, lamps inside the viewfinder and a warning tone.
Priority
Warning
type
LCD or
viewfinder
indication
Viewfinder
LED
(except tally)
Tally
lamp
Warning
lamp
Alarm
tone *
6
Warning description
and recording/
playback operation
Countermeasures
1
System
error
SYSTEM ERROR
Cause indication *
1
Red blinking
No
Blinks 4
times per
second
Blinks 4
times per
second
Continuous
tone
P2 microprocessor
or control failure.
Operation stops.
Check the cause
indication *
1
and
consult your
distributor.
2
Incorrect
P2 card
removal
TURN POWER
OFF
Blinks red
No
Blinks 4
times per
second
Blinks 4
times per
second
Continuous
tone
A P2 card was
removed during
access and card data
was corrupted.
All four access LEDs
blink orange (4 Hz)
Turn off the power.
Repair the P2 card if
the clips on the card
are corrupted.
3
The
battery is
exhauseted
LOW BATTERY
Red blinking, and
the battery level
bar blinks with
the empty status.
(This indication
appears also
when MENU
indications have
been turned OFF.)
No
Blinks 1
time per
second
Lights
Continuous
tone
The battery is
exhausted.
Recording and
playback stop.
The camera stops
automatically when
the voltage drops.
Replace the battery.
4
P2 card
fully
recorded
P2
FULL
Blinks red
(appears only for
3 seconds in MCR
mode.)
When SAVE
LED is set to
P2CARD, the
SAVE LED
blinks 4 times
per second.
Blinks 4
times per
second
after
completion
of
recording.
Lights
after
completing
recording
Continuous
tone after
completing
recording
No more space
on P2 cards left
for recording.Stop
recording. *
3
Delete clips that are
no longer needed or
insert a new card.
5
Recording
error
REC WARNING
Cause indication *
2
Blinks red
No
Blinks 4
times per
second
Blinks 4
times per
second
Intermittent
tone 4
times per
second
A recording error
has occurred. Stop
recording. *
4
Turn the power off
and then back on
again and check
recording and
playback. Replace
any P2 card that does
not enable normal
recording.
6
1394
connection
errors
1394INTIAL
ERROR
Blinks red
No
Blinks 4
times per
second
during
recording.
Blinks 4
times per
second
during
recording.
No
Incorrect 1394
connection or signal
input/output error.
Check camera and
external device
connections and
reconnect as
necessary. Then turn
the power off and
back on again.
7
PC mode
1394
HOST
connection
error
No No
Blinks 4
times per
second
Blinks 4
times per
second
No
The 1394 cable
has become
disconnected or
multiple devices are
connected. (Normal
PC mode operation is
possible.)
Connect a hard disk
drive according to
supplied operating
instructions.
142


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Panasonic AG-HPX 500P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Panasonic AG-HPX 500P in the language / languages: English as an attachment in your email.

The manual is 12,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info