656390
2
Zoom out
Zoom in
Previous page
1/4
Next page
Normal programme
In mode “1..7” program as week (no date function)
The weekly programmes will run continuosly, week
by week, as long as neither special programme nor
perm ON or OFF is activated.
Special programme(s)
Special programmes must be programmed in func-
tion “SP 1..7” (as per week programme).
Special programmes can be selected
(START/STOP Times) in “SP Date” function.
According to the “SP date” inputs the time switch
changes from the normal weekly programme to the
required No. of the special programme.
Some rules for the programming of SP-special
programmes
• Each special programme can be activated as often
as required, but only within the available storage
capacity.
• If, by mistake several special programmes are ac-
tivated within the same dates, only the special
programme with the highest priority (between SP1
and SP 15) will be carried out. The other special
programmes will be ignored.
• A special programme primarily programmed for
several channels can be activated to overwrite
one, two, three or four channels.
The remaining channel will continue with the
normal programme or carry out other activated
special programmes.
• When a special programme is activated it will take
priority over the normal programme.
Priority in switching
Highest priority Permanent ON or OFF,
(Programming mode “Date”)
P15 Special programme “SP 1..7”
and “SP DATE”
P01
Lowest priority Normal programme (Mode 1..7)
To store and save the programme of the time
switch.
To transfer the programme from the “Data key”
to the time switch.
To duplicate the programme in another
adequate time switch.
The “Data key” can be used in all function modes of
the time switch.
Store and save the programme in the “Data key”:
1. Insert “Data key” (Drawing 1). “CARD” is dis-
played.
2. Press key 1x “SAVE” is displayed.
3. Press key – programme transfer starts, “Pr”
displayed until programme is saved.
4. “Data key” can be removed out. (pulled out)
(Time switch is in mode AUTO)
If “Er” is displayed data storage was unsuccessful
due to the “Data key” being write protected. Move
switch to the “0” position and repeat process. If pro-
gramme is to be kept use new “Data key” for new
programme.
Transfer programme from “Data key” to the time
switch:
1. Insert “Data key” (Drawing 1). “CARD” is dis-
played.
2. Press key 2x “LOAD” is displayed.
3. Press key – programme transfer starts, “Pr”
displayed until programme is saved.
4. “Data key” can be removed out.
(Time switch is in mode AUTO)
Failure: “EP” is displayed,
when “Data key” is not compatible. (e.g. trying to
load a yearly programme into a week time switch)
Additional module: Data Storage Key
Yearly function
Beginning/end of summertime:
Mode 0:
4th sunday, each March and October
Mode 1:
Current Central European Regulation
last Sunday, each March and October (installed)
Mode 2:
input of individual dates possible
(dates from mode 1 can be over written)
Mode 3:
no summertime change
Mode 4:
Last Sunday, each March and September
Mode 5:
1st Sunday in April, last Sunday in October (USA)
• Disconnect time switch from main.
• Connect receiver according to wiring diagram.
• Reconnect time switch to mains.
• Radio symbol flashing in display for approx
3 minutes.
• If symbol continues to flash after 3 minutes there
is a fault or the time signal cannot be received.
• With receiver disconnected, no indication of radio
symbol.
In both cases the time switch is running quartz-
controlled.
DCF 77 is an european generated signal and is not
availible in the UK.
RED: Flashing symbol in display
Example: Date 14.07.1999
Time 14:30
Initial form: Mode AUTO
Press
4x
1x
1x
4x
2x
6x
2x
9x
1x
1x
1x
4x
1x
3x
2x
Mode
Current date and real time input or change
Examples
DCF 77 time signal receiver
Time switch can be connected to a receiver
of DCF 77 time signal
Mode S/W summertime changes
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
Several possibilities:
1. Single day, one channel
2. Several days, one channel
3. Single day, several channels
4. Several days, several channels
Example: Thuesday (2) and Thursday (4), switching
time 19:00 h; Channel A ON, channel B
IMPULSE 10 sec.
Initial form: Mode AUTO
PRESS 1x
1x
1x
1x
1x
3x
1x
1x
9x
3x
1x
1x
3x
3x
1x
2x
After approx.
3 sec.:
Continue with input of further dates/functions or
press key 7x to return to mode AUTO
Example: Wednesday (3); Time 14:00
Channel D OFF
Initial form: Mode AUTO
PRESS 1x
2x
1x
4x
1x
1x
4x
3x
If 1x (once through) is required (one day of the week
only) press key to confirm 1x.
Input will be cancelled automaticly after execution.
Excample without 1x.
Mode 1..7
Programming normal weekly programmes
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
AUTO 1..7 DATE ? S/W 1..7 DATE
ı
– ––– S P ––––
ı
1X
EIN
A
US
chreibschutz
1
O
Zeichnung 1
Overwriting
OFF
protection
ON
drawing 1
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Paladin 179 640 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Paladin 179 640 in the language / languages: English as an attachment in your email.

The manual is 0,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Paladin 179 640

Paladin 179 640 User Manual - German - 4 pages

Paladin 179 640 User Manual - Dutch - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info