6. Under “System standby” option, choose “Never” in
drop down menu.
7. Click “Apply” and then click “OK”.
8. Previous window will return. Click “OK” to confirm
and exit.
RESET
Press RESET to return to the default settings.
TROUBLE SHOOTING
PROBLEM SYMPTOM REMEDY
Sensor
Icons are not
displayed.
1. Check sensor
batteries
2. Check if sensors
are within range
3. Check USB
communications
hub is connected
to USB
PC Cannot upload 1. Check the PC
software is setup
and running
2. Check PC is
c o n n e c t e d
with the USB
communications
hub via USB
SPECIFICATIONS
USB COMMUNICATIONS HUB
Dimensions 68 x 46 x 136 mm
(L x W x H) (2.7 x 1.8 x 5.4 inches)
Weight 92 g (0.2 lbs) without battery
INDOOR BAROMETER
Barometer unit mb/hPa, inHg and mmHg
Measuring range 700 – 1050mb/hPa
Accuracy +/- 10 mb/hPa
Resolution 1mb (0.0 inHg)
Altitude setting Sea level
User setting for compensation
Weather display Sunny, Clear night, Partly Cloudy,
Cloudy, Cloudy at night, Rainy
and Snowy
Memory Historical data and bar chart for
last 24hrs
INDOOR TEMPERATURE
Temp. unit °C / °F
Displayed range 0°C to 50°C (32°F to 122°F)
Operating range -30°C to 60°C (-4°F to 140°F)
Accuracy 0°C - 40°C: +/- 1°C (+/- 2.0°F)
40°C - 50°C: +/- 2°C (+/- 4.0°F)
Comfort 20°C to 25°C (68°F to 77°F)
Memory Current, Min and Max temp.
Dew Point w/ Min and Max
Alarm Hi / Lo
INDOOR RELATIVE HUMIDITY
Displayed range 2% to 98%
Operating range 25% to 90%
Resolution 1%
Accuracy 25% - 40%: +/- 7%
40% - 80%: +/- 5%
80% - 90%: +/- 7%
Comfort 40% to 70%
Memory Current, Min and Max
Alarm Hi / Lo
REMOTE WIND SENSOR UNIT
Dimensions 178 x 76 x 214 mm
(L x W x H) (7 x 3 x 8.4 inches)
Weight 100 g (0.22 lbs) without battery
Wind speed unit m/s, kph, mph, knots
Speed accuracy 2 m/s ~ 10 m/s (+/- 3 m/s)
10 m/s ~ 56 m/s (+/- 10%)
Direction accuracy 16 positions
Transmission of Approx. every 14 seconds
wind speed signal
Memory Max speed gust
Battery 2 x UM-3 (AA) 1.5V batteries
OUTDOOR TEMPERATURE / HUMIDITY UNIT
RELATIVE TEMPERATURE
Dimensions 115 x 87 x 118 mm
(L x W x H) (4.5 x 3.4 x 4.6 inches)
Weight 130 g (0.286 lbs) without battery
Temp. unit °C / °F
Displayed range -50°C to 70°C (-58°F to 158°F)
Operating range -30°C to 60°C (-4°F to 140°F)
Accuracy -20°C – 0°C: +/- 2°C (+/- 4.0°F)
0°C - 40°C: +/- 1°C (+/- 2.0°F)
40°C - 50°C: +/- 2°C (+/- 4.0°F)
50°C - 60°C: +/- 3°C (+/- 6.0°F)
Comfort 20°C to 25°C (68°F to 77°F)
Memory Current, Min and Max temp.
Dew Point w/ Max and Min
Wind chill temp. and min
RELATIVE HUMIDITY
Displayed range 2% to 98%
Operating range 25% to 90%
Resolution 1%
Accuracy 25% - 40%: +/- 7%
40% - 80%: +/- 5%
80% - 90%: +/- 7%
Comfort 40% to 70%
Memory Current, Min and Max
Battery 2 x UM-4 (AAA) 1.5V batteries
RF TRANSMISSION
RF frequency 433MHz
Range Up to 100 meters (328 feet) with
no obstructions
Transmission Approx. every 60 seconds
No. of Channel 1 for Wind/ Rain/ UV and 10 for
Temp. / Humidity
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific WMRS200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific WMRS200 in the language / languages: English as an attachment in your email.

The manual is 3,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oregon Scientific WMRS200

Oregon Scientific WMRS200 User Manual - German - 10 pages

Oregon Scientific WMRS200 User Manual - Dutch - 9 pages

Oregon Scientific WMRS200 User Manual - French - 9 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info