Note: Yesterday’s rainfall record will be updated when the real time
clock runs from 11:59:59 pm to 12:00:00 am. And it is counted for
12:00:00 am of one day to 12:00:00 am on the next day.
If the rain sensor detects no rainfall for about two consecutive
hours, the current rate of rainfall will be displayed as zero.
To clear the total rainfall,
1. Press the rainfall window.
2. Press and hold [MEMORY] till the key tone is heard.
The yesterday’s rainfall record will not be affected when you clear
the total rainfall.
WIND SPEED AND DIRECTION
The current wind speed and direction are displayed in the wind
speed and direction window.
To display the average wind speed, press the window till the
“AVERAGE” icon is displayed.
The wind speed can be displayed in m/s, kph, mph or knots.
To select the display unit,
1. Press the wind speed and direction window.
2. Press [UNIT] for the desired setting.
To display the maximum speed and direction for gust wind in
record,
1. Press the wind speed and direction window.
2. Press [MEMORY]. The time and date of the record will also be
displayed aternatively with “STAMP” icon in the clock window.
To clear the record,
1. Press the wind speed and direction window.
2. Press and hold [MEMORY].
As for the wind direction, it is displayed in a digital compass with
bearing readouts.
WEATHER ALARMS
Weather alarms are used to alert you to certain weather conditions.
Once activated, the alarm will go off when a certain set criterion is
met.
You can set alarms for:
· Indoor, outdoor and channel high temperatures
· Indoor, outdoor and channel low temperatures
· Indoor, outdoor and channel dew point approaching
· Indoor, outdoor and channel high humidity
· Indoor, outdoor and channel low humidity
· High rainfall rate
· Pressure drop
· High gust wind
· Low wind chill
To set a weather alarm,
1. Press the window containing the weather element you want to
set.
2. Press [ALARM]. The current alarm setting will be displayed.
OUTDOOR AND CHANNEL HUMIDITY
The relative humidity readings taken by the outdoor thermo-
hygrometer and separate thermo-hygro sensors are displayed on
the outdoor/channel humidity window.
As this window can display up to four different sets of data, specify
the instrument or channel you want to read.
To do so,
1. Press the outdoor/channel humidity window.
2. Press [CHANNEL] to go from the outdoor reading taken by the
thermo-hygrometer to those taken by individual sensors
(Channel 1, 2 or 3).
To display the maximum, minimum and current humidity,
1. Press the outdoor/channel humidity window.
2. Press [CHANNEL] for the outdoor thermo-hygrometer or the
desired channel.
3. Press [MEMORY] repeatedly for the desired record. The time and
date of the record will also be displayed alternatively with
“STAMP” icon in the clock window.
To clear the memory,
1. Press the outdoor/channel humidity window.
2. Press [CHANNEL] for the outdoor thermo-hygrometer or the
desired channel.
3. Press and hold [MEMORY] till the key tone is heard.
4. Press [MEMORY] to check the memory is clear.
AUTO SCANNING FUNCTION
The auto scanning function is avalibable for the outdoor/channel
window for both the temperature and humidity.
To use it,
1. Press the outdoor/channel temperature or humidity window.
2. Press and hold [s] . The main unit will start scanning from the
active temperature and humidity display. Each channel will be
displayed for about 4 seconds.
To exit the auto scanning routine, press any window or control
button.
RAINFALL
The rate of rainfall can be displayed in mm/hr or in/hr.
To select the display unit,
1. Press the rainfall window.
2. Press [UNIT] for the desired setting.
To display the yesterday’s rainfall and the total rainfall from the
last cleared date,
1. Press the rainfall window.
2. Press [MEMORY] for the desired record. Yesterday rainfall will
be displayed with “YESTERDAY” shown in the rainfall window.
Total rainfall will be displayed with "TOTAL" shown in the
rainfall window. The time and date of the record will be displayed
alternatively with “SINCE” icon in the clock window for total
rainfall.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific WMR918 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific WMR918 in the language / languages: English as an attachment in your email.

The manual is 0,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info