EN
TEMPERATURE AND HUMIDITY
You can view the current indoor/outdoor temperature/heat index, humidity, dew-point
and the max/min memories on the base station.
Select the temperature unit on App: oC (for EU)/oF(for US).
To view current temperature, heat index and TODAY MAX/MIN readings on the
device:
1. Press SELECT repeatedly to navigate icon to the temperature/heat index area.
2. Press MODE repeatedly to toggle between the temperature/heat index displays.
3. Press MAX / MIN to toggle among current / MAX /MIN readings.
4. Press or to change channel (outdoor temperature only).
To view humidity, TODAY MAX/MIN and dew-point readings on the device:
1. Press SELECT repeatedly to navigate icon to the humidity/dew-point area.
2. Press MODE repeatedly to toggle between the humidity/dew-point displays.
3. Press MAX / MIN to toggle among current/MAX/MIN readings.
NOTE The heat index provides an indication on how hot it feels based on air
temperature and relative humidity.
NOTE
The dew point advises at what temperature condensation will form.
TEMPERATURE AND HUMIDITY TREND
The trend lines are shown next to the temperature and humidity readings. The trend
is shown as follows:
RISING STEADY FALLING
WIND CHILL / DIRECTION / SPEED
You can view and set the numeric wind speed with maximum memory display on our
dedicated App.
Select the wind units on the App.
Kilometers per hour (kph)
Miles per hour (mph)
Meters per second (m/s)
Knots (knots)
View on the device:
The base station provides wind speed and wind direction information.
To read the wind direction, nd the compass point is pointing to.
To select wind display mode:
Press MODE on wind area to toggle between:
GUST (Gust)
AVG (Average)
The wind level is shown by a series of text icon:
LIGHT MODERATE STRONG STORM
2 -8 mph
(3-13 km/h) 9-25 mph
(14-41 km/h) 26-54 mph
(42-87 km/h) >55 mph
(>88 km/h)
To read the wind direction:
Status Wind Direction Indicator Meaning
GUST Real-time wind direction
AVG Real-time average wind direction
AVG (Max 6 sets) Wind direction of last hour
To view today maximum wind speed and minimum wind chill readings:
1. Press SELECT repeatedly to navigate icon to the wind speed/wind direction/
wind chill area.
2. Press MAX / MIN to toggle between current/MAX wind speed and current/MIN
wind chill readings.
NOTE The wind chill factor is based on the combined effects of temperature and
wind speed.
UV/RAINFALL/ BAROMETRIC PRESSURE/PM
The station is capable of displaying the UV index, the current or past 24 hours of
rainfall, max rain rate, barometric pressure and air quality readings.
RAINFALL
To view the recorded rainfall/rain rate of the current hour or past 24 hours:
1. Press SELECT repeatedly to navigate icon to the UV/Rainfall area.
2. Press MODE repeatedly to select .
3. Press MAX / MIN repeatedly to toggle among current / today max rain rate, past
24 hours, or today accumulated rainfall readings.
Select the measurement unit for the rainfall/rain rate on the App:
mm (millimeter); in (inch)
mm/hr (millimeter per hour); In/hr (inch per hour)
UV INDEX (OPTIONAL)
To view the UV reading:
1. Press SELECT repeatedly to navigate icon to the UV/rainfall area.
2. Press MODE repeatedly to select .
3. Press MAX / MIN to toggle between current/MAX UV index display.
BAROMETRIC PRESSURE
To view the barometric pressure reading:
1.
Press SELECT repeatedly to navigate icon to the barometric pressure/PM area.
2. Press MODE repeatedly to select .
To view pressure trend:
The barometric pressure trend icons are based on recent sensor readings.
The trend lines are shown next to the pressure readings. The trend is shown as
follows:
RISING STEADY FALLING
Select the measurement unit for the barometer on the App:
Barometric pressure: mmHg (Millimeters of mercury)
inHg (inches of mercury), mbar (millibars)
hPa (hectopascal).
Set the altitude level compensation:
The altitude reects the distance from sea level at your position. You can set the
altitude level compensation for the barometric pressure readings on the App.
NOTE When altitude is set to 0 meter, the pressure reading is the local pressure.
If the altitude is set to the current location, the new pressure reading is an offset
pressure to the sea level.
PM (OPTIONAL)
To view the PM reading:
1. Press SELECT repeatedly to navigate icon to the Barometric pressure/PM
area.
2. Press MODE repeatedly to select PM 2.5, PM10, AQI.
Select the measurement unit ppm or ug/m3 for the PM on the App.
BACKLIGHT
Press any button on the base station to activate the backlight.
RESET
Press and hold and together for 5 seconds to return the device to default
settings.
*DO NOT RESET WITHOUT FIRST REMOVING YOUR DEVICE IN THE APP
MAINTAINANCE
Maintain the Rain Gauge
Clean the hole of the rain collector and the debris collector for maintaining accuracy is
very important. Unscrew the debris collector and clean the dirt by water periodically.
Maintain the Wind Sensor
If the wind cup doesn’t spin in the wind or does not spin as fast as they should.
Remove the wind cup and clear out all bugs, spider webs or debris.
NOTE
Do not apply any uid lubricant on the shaft and bearing. It probably breaks
the inner electronic components.
WMR500_EN R25.indd 5 2017/3/14 下午2:50
P/N: 300103876-00001-10 Rev1.0
6/70
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific WMR500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific WMR500 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 10.1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oregon Scientific WMR500

Oregon Scientific WMR500 User Manual - English, French, Spanish - 21 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info