EN
BAROMETER
1
2 3
8 7
4 5
6
1. Altitude area indicator
2. : Alarm for changes of barometric pressure
3. TODAY/MONTHLY/MIN/MAX: Display the maximum/minimum of today’s/
monthly barometric pressure reading
4. Barometer trend
5. Hourly records indicator (From -24 to 0)
6. inHg / mmHg / mb / hPa: Barometer unit
7. M / FEET: Altitude unit
8. Barometer reading
RAINFALL
8 7 6
5
4
3
1 2
1. HI alarm: Alarms for high rain rate and past 24-hour rainfall.
2. TODAY/MONTHLY/MAX: Display the maximum of today’s/monthly rainfall/rain
rate reading
3. Hourly records indicator (From -24 to 0)
4. RATE: Rainfall rate
5. THIS HOUR/ACCUM/PAST 24hrs: Selected time range
6. In/mm: Rainfall unit; In/hr / mm/hr: Rain rate unit
7. Rain reading display
8. Rain area indicator
INSTALLATION
Please prepare some tools before starting your installation. You may need some
types of screw drivers, wrenches or an electric drill.
SET UP RAIN SENSOR & THERMO / HYGRO SENSOR
The rain gauge collects rain and takes rainfall readings. The transmitter box can
wirelessly transmit data to the main unit.
1
2
1. Make sure the engraved arrow on the thermo/hygro sensor casing towards the
installation direction of the transmitter box.
2. Align three screw holes on the rain gauge with the three double end studs on
the thermo/hygro sensor casing.
3. Tightly twist the type B screws into the double end studs to make sure the
connection is firmly.
4. Put the rain collector on the rain gauge
aligning the tipping with the holes, and
then twist clockwise to secure it tightly.
5.
Put the plastic debris filter in the rain collector
.
NOTE
Cut away the cable tie on the tipping
bucket before using.
SET UP WIND SENSOR
The wind sensor takes wind speed and direction readings.
1. Loosen the screws in the wind cups and wind vane.
2. Insert the top of the wind sensor unit into the wind cups securely with some
pressure and then twist the screw tightly.
3. Insert the bottom of the wind sensor unit into the
wind vane securely with some pressure and then
twist the screw tightly.
NOTE
There is a rubber washer around the top of
the wind sensor for preventing from hard touching
during installation. You can move up the rubber
washer a little bit before inserting the wind cup.
SET UP TRANSMITTER BOX
1. Approach the mounting ring of the transmitter box to the rain gauge, and align
mounting ring with the bottom of the hole of the rain gauge.
2. Insert the mounting insert into the mounting ring of the transmitter box through
the hole of the rain gauge with some pressure. A click sound can be heard.
NOTE
The transmitter box contains sophisticated electronic parts, so you must
treat it with care.
CABLE CONNECTIONS
It is better you connect the cables of each sensors
to the transmitter box before positioning the pole.
1. Unscrew to open the transmitter box.
2. Take off the rubber stopper from the cable slot.
3. Insert all the sensor cables through the cable slot.
4. Plug each sensor cable into corresponding
socket that has name below the socket for
recognition. A click sound can be heard.
5. Return the rubber stopper to the cable slot.
R
A
I
N
T
H
W
I
N
D
W
I
N
D
T
&
H
R
A
I
N
R
A
I
N
T
H
W
I
N
D
W
I
N
D
T
&
H
R
A
I
N
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific WMR300A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific WMR300A in the language / languages: English as an attachment in your email.

The manual is 10,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info