WIND CHILL (Wind chill)
WIND (Wind speed)
BARO (Barometer)
RAINFALL (Rain)
To select time range display mode:
Press bar chart area to toggle the chart records between the following
time ranges.
LAST 24 HRS (Past 24 hours)
LAST 24 DAYS (Past 24 days)
LAST 24 MTHS (Past 24 months)
To select record range display mode:
Press
bar chart area, and then press to toggle the chart records
between the following ranges.
MAX (Maximum record)
MIN (Minimum record)
NOTE
The purpose of the bar chart is to provide a quick comparison between
the records. Changing the measurement unit will have corresponding effect on
the bar chart display.
MEMORY
MAX / MIN OF TODAY / MONTHLY RECORDS
Area Type of Memory Indicators
Temperature
Current indoor /
outdoor temperature
MONTHLY
MAX
MIN
TODAY
MAX
MIN
Heat index
MONTHLY
MAX
TODAY
Wind chill
MONTHLY
MIN
TODAY
Dewpoint
MONTHLY
MAX
TODAY
MIN
Humidity
Current indoor /
outdoor humidity
MONTHLY
MAX
MIN
TODAY
MAX
MIN
Wind Gust wind speed
MONTHLY
MAX
TODAY
Barometer Barometer
MONTHLY
MAX
MIN
TODAY
MAX
MIN
Rain
Rain rate
MONTHLY
MAX
TODAY
Rainfall
MONTHLY
MAX
TODAY
To view memory records:
1. Press desired area to activate.
2. Press
to toggle between MIN/MAX of TODAY/MONTHLY
recorded readings.
To clear individual area records:
1. Select a record in memory.
2. Press and hold for 2 seconds.
3. Delete process is complete when display changes to current reading.
NOTE
When MAX/MIN reading displays, the corresponding timestamp will be
displayed in the area
HOURLY RECORDS
Display Hourly readings of up to
Barometer 24 hours back
Hourly Rainfall 24 hours back
To view hourly records:
1. Press desired area to activate until the hour frame displays.
2. Press or to view current (0 hr) / hourly reading
(from -1hr to -24hr).
DATA LOG
The weather data can be automatically saved by setting data logger, and then you
can view the data through a PC program by uploading to the PC.
To set data log:
1. Press
area, then press to activate DATA LOG mode.
2. Press and hold
.
3. Press
or to select frequency of data recording (1 / 5 / 15
/ 60 minutes).
4. Press
.
5. Number of days memory will allow for records will be displayed.
Frequency In Minutes
No. of Days Available for Data Logging with
Memory Available
1 22D (3 weeks)
5 113D (3.5 months)
15 341D (10.5 months)
60 1364D (3.5 years)
To view remaining days for records:
Press area.
NOTE
When DATA LOG is almost full, DATA LOG flashes to remind you to
transfer the data to PC for storage. Otherwise, data logger cannot log any more
data when it is full.
To upload records to PC:
Plug the small end of the USB cable to USB port on the main unit and the big end
of the cable into the USB port of the PC. The records will be uploaded onto the
software run by the PC via the USB cable.
displays in area on main unit.
NOTE
PC program provided must be installed before uploading of records from
main unit.
To clear records:
1. Press
area, then press , DATA LOG displays.
2. Press and hold
.
3. After all the data cleared, the display shows the new time remaining. Delete
process is complete and successful.
ALARM
Weather alarms are used to alert you of certain weather conditions. Once activated,
the alarm will turn on and start flashing when a certain criterion is met. The alarm
does not flash and goes back to normal until the reading is not beyond the alarm
setting anymore.
Area Type of Alarm
Clock Daily alarm
Temperature
Current indoor / outdoor temperature
HI
LO
Heat index HI
Dew point
HI
LO
Wind chill LO
Humidity Current indoor / outdoor humidity
HI
LO
Wind Gust wind speed HI
Barometer Barometric pressure *
Rain
Rain rate HI
Past 24-hour rainfall HI
*Barometric pressure alarm is a pressure drop alarm
To set the alarm:
1. Press desired area to activate.
2. Toggle
to display current reading and HI / LO alarm.
3. Press and hold
.
4. Press
or to set the desired values.
5. Press
to confirm and continue to next setting
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific WMR300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific WMR300 in the language / languages: English as an attachment in your email.

The manual is 10,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oregon Scientific WMR300

Oregon Scientific WMR300 User Manual - English, German, Dutch, French, Italian, Portuguese, Swedish, Spanish - 131 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info