3
1 2
97 8 10 11 126
3
4
5
13
RESET
KEY
UV SOLAR RAIN TH WIND
Figura 3 - Vista interior
1. Tomada para adaptador de energia (opcional)
2. Interruptores deslizantes para configuração de
canais (SW1)
3. Conetor com código de cores para ligação do
painel solar
4. Compartimento para pilhas recarregáveis
5. Botão RESET
6. Botão KEY: para calibração da direção do vento
7. Tomada de sensor UV (indisponível de momento)
8. Tomada de sensor SOLAR (indisponível de momento)
9. Tomada de sensor de RAIN(CHUVA)
10. Tomada de TH (sensor de temperatura & Umidade)
11. Tomada de sensor de WIND (VENTO)
12. Interruptor deslizante de emparelhamento (SW4)
13. Luzes LED (azul/verde/vermelho)
SENSOR DE TEMPERATURA & UMIDADE
1
2
4
53
Figura 4
1. Parafusos (tipo B)
2. Cápsula do sensor
3. Sensor de temperatura e umidade
4. Parafusos (pré-instalados)
5. Cabo do sensor
MONTAGEM DO SENSOR
Para uma melhor montagem e mais fácil configuração,
descarregue o manual de instruções do WMR300/
WMR300A através da ligação abaixo:
http://weather.oregonscientific.com/products_wmr300.asp
Para montar corretamente o seu sensor pode ser
necessário algumas ferramentas -- nomeadamente,
chave de fendas, chave inglesa e um furadeira. O tipo
de ferramenta que precisa vai depender de como vai
montar o sensor.
A caixa do transmissor tem uma capacidade de
transmissão de dados por wireless com um alcance
de aproximadamente 300m (984 pés). A localização
ideal para o sensor será no telhado de um edifício em
zona aberta, longe de árvores ou outros obstáculos que
possam impedir uma leitura exata. Deve também colocar
a caixa do transmissor sob a luz direta do sol, para um
melhor fornecimento de energia do painel solar.
Orientação do painel
solar:
Se vive no:
Norte Hemisfério sul
Sul Hemisfério norte
NOTA
Coloque o termômetro
& sensor de umidade a, pelo
menos, 1,5 metros de altura
para evitar que a temperatura
do solo afete a exatidão do
termômetro & sensor
de umidade.
1.5MM
Ground
53


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific THGN301 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific THGN301 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Swedish, Spanish as an attachment in your email.

The manual is 23.95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info