589204
8
Zoom out
Zoom in
Previous page
1/12
Next page
F
7
NOTE
AVERTISSEMENT PILES FAIBLES
Remplacez les piles lorsque le signal piles faibles (
)
s'affiche sur l'unité extérieure ou dans la zone unité
extérieure de l'unité principale.
N'utilisez pas de piles rechargeables. Ne jetez
pas les piles usagées, mais rapportez-les à une station
de rebut agréée.
RÉINITIALISATION DU SYSTÈME
Le bouton RESET se trouve dans le compartiment
des piles. Appuyez dessus avec la pointe d'un objet
pointu (tel qu'un stylo à bille) chaque fois que vous
remplacez les piles ou qu'une performance n'est pas
satisfaisante (par exemple, impossibilité d'établir une
liaison radio avec l'unité principale). Reportez-vous au
Manuel de l'utilisateur de l'unité principale pour plus
d'informations.
PS R01 French r7 8/6/03, 12:52 PM7
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific PSR01 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific PSR01 in the language / languages: French as an attachment in your email.

The manual is 0,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oregon Scientific PSR01

Oregon Scientific PSR01 User Manual - English - 11 pages

Oregon Scientific PSR01 User Manual - German - 12 pages

Oregon Scientific PSR01 User Manual - Dutch - 11 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info