589231
7
Zoom out
Zoom in
Previous page
1/12
Next page
7
GB
To deactivate the remote-sensor scanning mode:
Press any button.
MAXIMUM AND MINIMUM
TEMPERATURE AND HUMIDITY
The maximum and minimum recorded temperature and humidity
readings will automatically be stored in the memory.
To display the maximum and minimum display memory:
1. Select the channel to be checked.
2. Press MEM/CLEAR once to display the maximum temperature
and again the minimum temperature. The respective indicators,
MAX or MIN will be displayed.
To clear the memory:
Press and hold MEM/CLEAR for 2-seconds.
If you press MEM/CLEAR now, the maximum and minimum tem-
peratures will have the same values as the current ones until
different readings are recorded.
HOW TO USE CHANNEL-1
TEMPERATURE/HUMIDITY ALARM
Upper and lower temperature and humidity limits for channel-1 can
be set so that an alarm activates when the limits are exceeded.
The high and low temperature and humidity displays are selected
by sequentially pressing HI/LO.
The high-low displays are as follows:
Sequence Respective Display
Pressing HI/LO once Enters HI temperature display
Pressing HI/LO twice Enters HI humidity display
Pressing HI/LO three times Enters LO temperature display
Pressing HI/LO a four time Enters LO humidity display
To set a high or low temperature or humidity alarm:
1. Press HI/LO, channel-1 will be displayed.
2. Press
to set the temperature or humidity limit. Each press will
increase increments by one degree or percentage. Press and
hold the button for a rapid-scrolling sequence by increments of
five.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific EMR812HGN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific EMR812HGN in the language / languages: English as an attachment in your email.

The manual is 0,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oregon Scientific EMR812HGN

Oregon Scientific EMR812HGN User Manual - German - 13 pages

Oregon Scientific EMR812HGN User Manual - Dutch - 12 pages

Oregon Scientific EMR812HGN User Manual - French - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info