6
To fold out the stand: To use the wall mount:
For best results:
Insert the batteries and select the unit, channel, and
radio signal format before you mount the sensor.
Place the sensor out of direct sunlight and moisture.
Do not place the sensor more than 70 metres
(230 feet) from the main (indoor) unit.
Position the sensor so that it faces the main (indoor)
unit, minimizing obstructions such as doors, walls,
and furniture.
Place the sensor in a location with a clear view to
the sky, away from metallic or electronic objects.
Position the sensor close to the main unit during cold
winter months as below-freezing temperatures may
affect battery performance and signal transmission.
The transmission range may vary and is subject
to the receiving range of the main unit.
You may need to experiment with various locations to
get the best results.
SENSOR DATA TRANSMISSION
Data is sent from the sensor(s) every 60 Seconds. The
reception icon shown in the Temperature / Humidity Area
indicates the status.
NOTE
SEARCH FOR SENSOR
To search for a Thermo / Hygro sensor, press SELECT
to navigate to the Temperature / Humidity Area.
will
show next to the Area. Then, simultaneously press and
hold MEMORY and CHANNEL for 2 seconds.
To search for the UV sensor, press SELECT to navigate
to the UVI / Barometer Area.
will show next to the
Area. Then, press and hold MEMORY and CHANNEL
for 2 seconds.
If the sensor is still not found, check the
batteries.
ICON DESCRIPTION
Main unit is searching for
sensors.
At least 1 channel has been
found.
Sensor 1 is sending data. (The
number shows which sensor is
selected.)
The selected sensor cannot be
found. Search for the sensor or
check batteries.
--- shows in Temp /
Humidity Area
NOTE
CLOCK AND CALENDAR
This product tracks the time and date based on radio-
controlled signals from the RTGR368N remote sensor,
or manual settings that you enter.
RADIO-CONTROLLED CLOCK
The time and date are automatically updated by radio-
controlled clock signals from official time-keeping
organizations in Frankfurt (Germany) and Rugby
(England) unless you disable this feature. The signals
are collected by the remote sensor (RTGR368N)
whenever it is within 1500 km (932 miles) of a signal.
Initial reception takes 2-10 minutes, and is initiated when
you first set up the unit, and whenever you press RESET.
Once complete, the reception icon will stop blinking.
The
icon shown in the Clock Area indicates
2 factors:
Connection between the main unit and the sensor
that collects RF signals (
)
RF signal reception (
)
How these signals work together:
ICON MEANING
The unit has contact with the
sensor and has synchronized
the time.
The unit has contact with the
sensor but the time has not
been synchronized.
The unit has lost contact with
the remote sensor but the time
is synchronized.
The unit has lost contact with
the remote sensor and the time
is not synchronized.
The unit cannot reach the
remote sensor.
To force a manual search for RF clock reception,
press and hold SEARCH on the sensor (RTGR368N)
for 2 seconds.
TURN RADIO-CONTROLLED CLOCK ON / OFF
If you wish to manually set the clock, you must first
disable the radio-controlled feature. To do this, navigate
to the Clock / Alarm Area. Then, press and hold DOWN
on the main unit for 2 seconds. To enable it, navigate to
the Clock / Alarm Area, then press and hold UP for
2 seconds.
NOTE
BAR933HG Eng R4 7/26/04, 9:26 PM6
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific BAR936HG at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific BAR936HG in the language / languages: English as an attachment in your email.

The manual is 0,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oregon Scientific BAR936HG

Oregon Scientific BAR936HG User Manual - German - 16 pages

Oregon Scientific BAR936HG User Manual - Dutch - 15 pages

Oregon Scientific BAR936HG User Manual - French - 15 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info