589273
8
Zoom out
Zoom in
Previous page
1/15
Next page
8
GB
To display the maximum and minimum display memory:
1. Select the channel to be checked.
2. Press [MEM] once to display the maximum temperature humidity
and again the minimum temperature humidity. The respective
indicators, MAX or MIN will be displayed.
To clear the memory:
Press and hold [MEM] for 2-seconds.
If you press [MEM] now, the maximum and minimum temperatures
will have the same values as the current ones until different readings
are recorded.
HOW TO USE CHANNEL-1 TEMPERATURE/
HUMIDITY ALARM
Upper and lower temperature and humidity limits for channel-1 can
be set so that an alarm activates when the limits are exceeded.
The high and low temperature and humidity displays are selected
by sequentially pressing HI/LO.
The high-low displays are as follows:
Sequence Respective Display
Pressing HI/LO once Enters HI temperature display
Pressing HI/LO twice Enters HI humidity display
Pressing HI/LO third time Enters LO temperature display
Pressing HI/LO fourth time Enters LO humidity display
To set a high or low temperature or humidity alarm:
1. Press [HI/LO], channel-1 will be displayed.
2. Press [ ] to set the temperature or humidity limit. Each press
will increase increments by one degree or percentage. Press and
hold the button for a rapid-scrolling sequence by increments of
five.
Note: The temperature range is from -50°C (-58°F) to +70°C
(158°F).
If this is the first time you set the limits, the lower limit will start
from -50°C (-58°F) and the upper limit +70°C (158°F). Other
wise, the reading will start from the temperature last selected.
The humidity range is from 2% to 98%.
If this is the first time you set the limits, the lower limit will start
from 2% and the upper limit 98% Otherwise, the reading will
start from the humidity last selected.
3. Repeat the steps to set the upper humidity setting and the lower
temperature and humidity settings.
4. When finished, press [HI/LO] to set another limit or wait 16-sec
onds and the unit will automatically return to the normal display.
The respective HI, LO or both indicators will light up to signify
the status of the alarm.
If in another channel other than channel one is selected, when the
alarm activates the display will switch to channel-1 and the display
will flash. If left untouched, the alarm will activate for a 1-minute.
Press any key to momentarily stop the alarm. The alarm will activate
again if the limit continues exceeds the set limit.
Note: If a second limit is passed while an alarm is active, the first
alarm will complete its 1-minute cycle and the alarm will continue
to activate for a second minute to indicate that a second limit has
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific BAR112HG at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific BAR112HG in the language / languages: English as an attachment in your email.

The manual is 0,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oregon Scientific BAR112HG

Oregon Scientific BAR112HG User Manual - French - 14 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info