520316
7
Zoom out
Zoom in
Previous page
1/14
Next page
7
GB
HOW TO READ THE KINETIC WAVE
DISPLAY
The kinetic wave display shows the signal receiving status of the
main unit. There are three possible forms:
The unit is in searching mode.
Transmission data are securely
registered.
No signal received in search mode.
REMOTE SENSOR SCANNING
The unit can be set to automatically scan and display readings from
the remote sensors and indoor readings. When the remote-sensor
mode is active, the display will show the readings from one channel
for about 4-second and then proceed to the next channel display.
To activate the remote-sensor scanning mode:
Press and hold [CHANNEL] for 2-seconds.
To deactivate the remote-sensor scanning mode:
Press either [CHANNEL], [MEM], [HI/LO], [ I ], [
ON / OFF]
(TEMP % RH AL)
THE COMFORT-LEVEL ICONS
The comfort level indicators COM, WET or DRY will tell you if the
current environment is comfortable, too wet or too dry.
The comfort indicator will appear on the display when the follow-
ing conditions are satisfied:
Indicator
displays
on the unit
COM
WET
Temperature
Range
20°C to 25°C
(68°F to 77°F)
-5°C -+ 50°C
(23°F - 122°F)
-5°C -+ 50°C
(23°F - 122°F)
Humidity
Range
40%RH-
70%RH
OVER-
70%RH
Below
70%RH
Shows that the
Current
Environment
Ideal range for
both relative
humidity and
temperature
Contains excess
moisture.
Contains
inadequate
moisture
No
Indicator
Less than
20°C( 68°F)
or More than
25°C (77°F)
40%RH
to
70%RH
No comment
DRY
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific BAR 182HG at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific BAR 182HG in the language / languages: English as an attachment in your email.

The manual is 0,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info