CALIBRATION
Menu Shortcut: Settings X Calibration
Virtual Weather Station allows you to calibrate for improved
accuracy. In addition, if your wind speed sensor is below the
expected reading due to bearing life or trees obstructing the
anemometer, these errors can be adjusted to provide realistic
values.
The calibration takes the form of the following equation:
Calibrated Value = Gain x Measured Value + Offset
The table provides solutions for typical measurement problems:
PROBLEM SOLUTION
The wind speed is reading 50% lower than it
should be because the sensor is obstructed
by trees. In other words, when the wind
speed reads 4.8 km/h (3 mph), it is actually
9.6 km/h (6 mph).
Set the wind speed
gain to 2.00.
One of my temperature sensors is off by 3° Set the temperature
offset to 3.00
I installed my anemometer incorrectly, and
when it point s north, it should measure south
Set the wind
direction offset to
180.00
Changing the calibration settings in Virtual Weather Station will not adjust the parameters displayed from
the console. Setting the gain to 0 will cause the value to always read 0. Only set the gain to 0 if you do not have
the sensor in your system.
PRECISION
Menu Shortcut: Settings X Precision
Precision is the number of decimal places that Virtual Weather
Station allows you to customize for each variable unless otherwise
noted on specific display panels. For example, a precision of two
would be represented as 3.14, and a precision of three would be
represented as 3.141. These precision values are represented in
files, HTML tags and other various displays.
The precision can be changed for the values (which include
averages) and rates of change. Changing the precision for the
temperature will change all of the temperatures (i.e., indoor and
outdoor).
4
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific AP 928 - WMR928NX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific AP 928 - WMR928NX in the language / languages: English as an attachment in your email.

The manual is 1,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oregon Scientific AP 928 - WMR928NX

Oregon Scientific AP 928 - WMR928NX User Manual - German - 26 pages

Oregon Scientific AP 928 - WMR928NX User Manual - Dutch - 29 pages

Oregon Scientific AP 928 - WMR928NX User Manual - French - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info